On CMS 's Promoting Interoperability Program (the program formerly known as the EHR Incentive Program)

A while back I read through CMS's recent rule changing the EHR Incentive program to the Promoting Interoperability program.  I promised a blog update but for some reason (work), didn't get around to writing it.  I decided to take action and finally sit down and finish it.

The published rule is something like 1800 pages, 36 reams of paper when printed double-spaced (as preprints are).  You can find it at the link above.  It goes by the precise but lengthy title of:

Medicare Program; Hospital Inpatient Prospective Payment Systems for Acute Care Hospitals and the Long-Term Care Hospital Prospective Payment System and Proposed Policy Changes and Fiscal Year 2019 Rates; Proposed Quality Reporting Requirements for Specific Providers; Proposed Medicare and Medicaid Electronic Health Record (EHR) Incentive Programs (Promoting Interoperability Programs) Requirements for Eligible Hospitals, Critical Access Hospitals, and Eligible Professionals; Medicare Cost Reporting Requirements; and Physician Certification and Recertification of Claims

I will only cover two parts: Quality Reporting Requirements, and the Promoting Interoperability Programs.  The first part is interesting because everyone who cares about the second part also has to deal with the quality reporting part.  You can find my raw read-through comments on Twitter.

Quality Reporting Requirements

If you haven't been paying attention to CQL, you really need to be.  The first publication of reporting requirements technical specifications will be this spring (coming REAL soon) for use in 2019 (coming sooner than you think).  According to CMS (and me) "We believe that compared to CQL, QDM logic is more complex and difficult to compute".  CMS will be using a sub-regulatory process to make technical corrections to the measure specifications.  This is good because it means that the quality measure specifications will be able to have more quality without going through a heavyweight process to fix mistakes.  But it also means you have to pay attention.

Hospital measure data will join the myriad of other public data out there, as it will .  Soon we'll be able to compare not just meaningful users and their EHR systems, but also the quality results they'll be able to get from the use of them.  That should be an interesting mashup.  Hey ONC! Are you listening?

A lot of measures are going to be eliminated, either because they are topped out (hospitals are doing so well its not worth measuring any more), duplicative, or cost too much to produce for value received or ...  There's are lists of the measures that CMS is proposing to remove in the rule.  While everyone is happy about measures being removed, just remember that also means that there are fewer choices to succeed with...

Promoting Interoperability Programs

Why did they change the name?  Well, they remind us in the rule that the EHR Incentive part of the program is about over for anyone participating (we're now in the penalty stage).  So that part makes sense.  One significant change is that the singular program became the plural programs. 

They are planning to require 2015 Certified EHRs for these programs because, in part, ONC has confirmed that at least 66 percent of eligible clinicians and 90 percent of eligible hospitals and CAHs have 2015 Edition available (see the link above at meaningful users and their EHR systems).  Also, the evaluation period is a minimum of any continuous 90-day period within each of the calendar years 2019 and 2020, as you all probably hoped and expect.  The rationale for this change was that health care providers may need extra time to fully implement and test workflows with the 2015 Edition of CEHRT.

Miscellaneous

Security Risk analysis is simply required, you don't get any extra points for doing what you are required by law and regulation to already do.

For ONC and CMS, it's pretty routine to ensure that whatever the latest and greatest healthcare crisis is, there needs to be something to in the regulations about it.  So new measures have been added to address opioid abuse, including Queries of prescription drug monitoring programs (PDMPs), and verification of opioid treament.

Closing the referral loop also gets some love with a new quality measure supporting that buzz phrase.

A number of exclusions (loopholes) are being removed, few are using them or they aren't warranted according to CMS.

Puerto Rico hospitals become eligible for the program, something that wasn't available to them previously.

Some capabilities will no longer be required to be used (though they will still exist in the certification requirement): Secure Messaging, View/Download/Transmit.

So, there you have it, my summary of about 10% of the rule.

For what it's worth

The section on Future Directions is worth reading for those of you who are worried about what is next, but that is merely non-binding self-promotion for the most part.  The really important part related to that is where CMS asks you to tell them where they should go.














Wednesday, March 16, 2016

ONC's statement of Purpose doesn't justify Certification Oversight Expansion

I just started reading the Expansion Rule and am finding myself both confused and alarmed.  At first blush, it all sounds good, but the ramifications are a bit, well, staggering.

First of all, I look at the justification for the expansion, which looks OK in part.  The bits about having oversight over the testing labs looks good, as does the fact that ONC will have a more direct role in addressing testing issues, and even the fact that they can do their own monitoring all seems OK.  But then I get to some of the concerning bits.

First of all, they cite patient safety as a possible trigger.  Now, ONC-ACB's are already certifying systems according to safety enhanced designed requirements, and I can see where if something came up with regard to patient safety where that was an issue, it becomes something that needs to be looked at, and frankly, as a patient, I'm very happy that ONC may decide to do its own looking.

But then there's this nebulous area where Certified components interacting with non-certified components come into play.  And that's where the challenge starts to show up.  This starts to give ONC oversight of EHR system components that aren't involved with the certification program, under some very loose reading of the statute as far as I can tell.

While the "purpose" for which ONC was created includes all the things they cite in the regulation, HITECH did NOT give ONC authority over all those topics described in the "Purpose".  Instead, it gave them a more narrow set of requirements focused (mostly) on creating a certification program, selecting standards, and coordinating federal efforts on HIT strategy and policy.

I don't see how using the purpose statements as a justification for expansion into EHR surveillance beyond the certification program comes into play, and given that loose reading ONC could also justify taking on a large number of other roles which overlap with other agencies responsibilities:

Under similar loose readings, one could suggest that:

  • Improving quality could authorize ONC to take on AHRQ responsibilities.
  • Reducing costs could authorize ONC to take on CMS responsibilities.
  • Just as reducing errors as presently used as a justification seems like it could authorize ONC to take on some of FDA's responsibilities.

This is a bad idea on several fronts.

If there's a patient safety issue with certified product, certainly ONC should address it.  Addressing product issues like that is already covered under the QMS (quality management system) requirements of meaningful use, and a failure of a vendor to adequately provide or execute on QMS for certified product would certainly apply in those cases.

But when we start talking about interactions with non-certified product, I have at least three concerns:

  1. Overlap with FDA requirements for those components that are classified under medical device regulations.
  2. Confusion about responsibilities when certified components and non-certified components are described as a single unit.
  3. Confusion about vendor responsibilities when the challenge may be introduced by product interactions between multiple vendors, some of which may be certified.
  4. Issues where the root cause could be "modification" in the field by non-vendor personnel.  

While ONC is rightly concerned that there need to be ways for some federal agency to act when a patient safety issue is discovered and not being appropriately addressed, neither its ACB's, nor frankly ONC, has the necessary experience to do so, and as I read the legislation, nor do they have the necessary authorization.

Attacking patient safety as an EHR Certification problem is not the right way to handle this.  Safety is built in, not bolted on.  Don't try to bolt it on to the certification process as an afterthought either.  Put some real thought into how to handle the safety issue, and don't confuse the two.  Talk to your colleagues over at FDA, they have a few decades of experience with addressing those sorts of challenges.

I've still got a lot more reading to do, this is just my first reaction to the first half of what I've read thus far.

   Keith

P.S. As a reminder, these are my own personal views, not those of my employer or anyone else.

Tuesday, January 19, 2016

Bring out Your Dead ...

ONC and CMS clarified today what the premature announcement of the death of Meaningful Use by Andy Lavitt last week means for Doctors and Hospitals:

  • Current law requires continued measurement of Meaningful Use as specified under existing regulations!  MACRA neither eliminates MU, nor makes it better.  But ONC and CMS are apparently listening well enough to put a good spin on things.
  • The M in MACRA stands for Medicare, and only affects physician and clinician payment adjustments. EHR incentive programs for hospitals still needs work.
  • The new approach will likely take a couple of years to figure out, though you can expect some of that regulation to start showing up later this year.
  • CMS will be making it easier for healthcare providers to claim hardship.


As Monty Python would say: "It's not dead yet!"

 

Tuesday, October 20, 2015

MeaningfulUse Stage3 Crosswalk

This spreadsheet cross walks from the Meaningful Use Objectives and Measures to the associated Certification Criteria and from thence to the standards. Thanks to Hans Buitendijk from Cerner for sharing this resource!  You can download it here.

   Keith


Friday, August 7, 2015

Moving forward from CCDA 1.1 to C-CDA 2.1

I just finished cleaning up the C-CDA 2.0 samples and reworking them for C-CDA 2.1.  As a result, I have a few notes already on what it takes to move up from 1.1 to 2.1 for those of you looking to plan ahead.

For any changed templates (there will be a list in C-CDA 2.1), you'll need to add the C-CDA 2.1 template identifier to your existing 1.1 template.

For problems, you'll need to add the LOINC equivalents in code/translation, as shown below.

<code code="64572001" displayName="Condition" codeSystemName="SNOMED CT" codeSystem="2.16.840.1.113883.6.96">
    <translation code="75323-6" displayName="Condition" codeSystemName="LOINC" codeSystem="2.16.840.1.113883.6.1"/>
</code>

<code code="409586006" displayName="Complaint" codeSystemName="SNOMED CT" codeSystem="2.16.840.1.113883.6.96">
    <translation code="75322-8" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Complaint"/>
</code>

For the vital signs organizer, you'll need to do something very similar.

<code code="46680005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Vital signs">
    <translation code="74728-7" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Vital signs"/>
</code>

And also for Cognitive Function.

<code code="2264892003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Number of pressure ulcers">
    <translation code="75277-4" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Number of pressure ulcers"/>
</code>

And Pressure Ulcers.
<code code='373930000' displayName="Cognitive function" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT">
    <translation code="75275-8" displayName="Cognitive function" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC"/>
</code>

And a few places where ASSERTION shows up.
<code code="ASSERTION" codeSystem="2.16.840.1.113883.5.4">
    <translation code="75321-0" displayName="Finding" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC"/>
</code>

You may yet find a few others, these were simply the ones that went on my electronic scratch pad as I did various edits to correct the samples.  This kind of stuff will take longer for an engineer to work out than it will to implement, probably on the order of 10:1.  So call it two weeks to design the changes, and then a day to implement them.  There's more to 2.1 than making it easy to move up a version, the main point was to retain compatibility with what's already in the field.  However, there's also some new stuff (like the Care Plan document), which will be incredibly valuable.

   Keith

P.S.  NOTE: While this post is tagged Stage 3 we have NO GUARANTEES that CCDA 2.1 will be named for Stage 3.  However, given how hard everyone has worked to make this happen, I am quite hopeful.

Tuesday, July 7, 2015

How Good it your CCDA Validator

I'm presently evaluating the HL7 C-CDA DSTU 2.1 update.  I'm doing it by way of updating the DSTU 2.0 sample files to conform to DSTU 2.1.  Along the way I've been testing my samples against both the 2.1 specification, and the 1.1 specification which it is to be backwards compatible with.

I have various validation tools for 1.1.  There's the Schematron produced by Trifolia, the TTT testing tool used for Meaningful Use, and the SITE Tool, as well as Josh Mandel's SMART CCDA Scorecard, and if I dug around hard enough, I could probably also find an Art Decor based validator.

Each one of these provides overlapping results.  Some are more up to date that others with HL7 Errata.  I'm still finding bugs with each of these so far.

One of the challenges that we have as an industry is that there is no single authority on what is a valid CCDA.  It should be HL7, but since ONC oversees the Certification program, and NIST develops the tools for that program, we have three different validators with slightly different ideas about what is a valid CCDA 1.1 document.

The validators are of varying quality with respect to how they work.  The Schematron-based tools are my favorite, simply because those tools are the most transparent about what they are testing.  None of the validation tools does a great job of taking me back to the source of truth used, although I can readily go from Conformance identifier back to the related specification.

I guess I'm spoiled by some of the W3C validators I've used, which link me directly to the conformance requirements in the standard.  Until we get an HTML version of CCDA, we won't be seeing that.  But hopefully that can be something that is produced sooner rather than later.

   Keith

Wednesday, July 1, 2015

CCDA 2.1 DSTU Update Available for Comment

I was quite please to see this cross my desk this afternoon.  It is the announcement of the request for comments on the C-CDA 2.1 DSTU Update.  As you may recall, this project was initiated at the May working group meeting.  We are now at the first of July, some six weeks after we initiated this project, and have knocked down our third duck (there are about three more to go).  We've done our best to make sure that there is plenty of time to get this into the Meaningful Use Stage 3 regulation, and now it is time for HL7 members to do their part.  Please have a look at the new material and provide your comments before July 13th.

   Keith


Hello,

The Consolidated CDA R2.1 DSTU update is available for member review.


SDWG will follow the review process outlined here: http://wiki.hl7.org/index.php?title=C-CDA_R2.1_Comment_Submission

Comment submission deadline: 7/13/2105 11:59 PM ET
Updates open for comment are identified by yellow highlighting.
·         Volume 1 - If the heading is highlighted, the entire section is open for comment.
·         Volume 2 - The specific conformance statements updated are highlighted. Templates that are only updated to reference a contained template that have been versioned (extension="2015-08-01") are not open for comment. Figures with updated conformance statements are open for review.

There are 3 methods to find edits:
2.     High-level change-log in Volume 1 (page 43)
3.     Excel comparison files (CDA R1.1 vs 2.0 Reviews) included in the review zip

All 3 methods should bring a reviewer to the same changes. Comment submission deadline: 7/13/2105 11:59 PM ET

Note, several R1.1/R2.0 errata are fixed in this release  -- all marked with 8/1/2015 (C-CDA R2.0/2.1) on our DSTU comments page (R1.1 / R2.0). SDWG is developing an R1.1/R2.0 errata summary which will be available prior to final publication of R2.1.

Best,
Brett

Brett Marquard
Principal
River Rock Associates

Thursday, June 11, 2015

How Transparency Enables Competition in a Market

So, I'm planning to have solar PV installed at my new house.  The state of Massachusetts and the federal government provide a lot of incentives to enable this.  I can get 30% of my installation cost back in federal tax credits, and something like $1000 from state credits, plus I can generate value through SRECs.  The state publishes a list of installers, as well as thes cost of installation in $/Watt. I've been using that list to pick solar companies to talk to.  The most popular installer also happens to be one of the more expensive, at $5.50/W, while others are in the $3.50 to $4.00 range.

In ONC's report on "Data Blocking", they note that pricing for interfaces is unknown.  Wouldn't it be interesting if incented providers under MU also had to report the price they paid for a system in order to get the incentive?

Oh, damn, the incentives are done. Maybe next time.


Thursday, May 28, 2015

Tell ONC to use CCDA 2.1 for Stage3 / 2015 Certification for MeaningfulUse !

Comments close shortly on the ONC Certification Proposed Rule.  If you've already submitted yours, I'd still like you to tell ONC three more things:

  1. HL7 is currently in the process of approving a project to update C-CDA 2.0 to 2.1 ensuring backwards compatibility with Version 1.1 named in previous Certification and Standards Rules.  This will avoid the unnecessary and potential dangerous situation of having to record two documents with dissimilar information about the same patient and encounter to support asynchronous bilateral cutover.  The project team hopes to complete this effort by July or August at the latest.
  2. The changes would enable a C-CDA compliant 1.1 system to read and understand as much of a C-CDA 2.1 instance as is technically feasible.
  3. We think this is a good idea, and would prefer it over other ONC suggested solutions (i.e., using 2.0 and sending two versions to support compatibility).
Click here to comment on the rule.  If you want to copy and paste my words above into your comment, feel free to do so!

     Keith

P.S. SDWG approved the PSS today!  On to the next stages.


Thursday, April 2, 2015

Your problem is not ours

This is a recurring theme for a lot of capabilities being suggested for meaningful use.  The you and us in this this case are the US Federal Government (represented by CMS, ONC, CDC and others) and healthcare IT stakeholders respectively.

How does this show up?

Vaccine Inventory: A physician's EHR is intended to capture information about clinical care of patients, not to manage national inventories of vaccines.  Aren't there better ways to capture this?  I know we already send a lot of this data to local public health in other ways, why do you need to push this onto the EHR?  In this particular example, I might agree that some Health IT may need to track vaccine inventory, and that other codes (such as NDC) may be applicable, I do NOT agree that these should be necessary exchanged in clinical documents designed to support clinical care.  Use the right tool for the job.

Fraud Investigation: Some parts of CMS would like for to us to create an electronic process to support fraud investigations, which as described in the 2015 certification rule requires some three different digital signatures in our health IT systems.  This to replace an existing process where they presently accept faxed copies of documents with wet signatures, in some cases applied by a stamp. All these signatures are in service of what?  Who is going to pay for the additional digital signature infrastructure?  Where is the governance of these certificates?  How will this be governed?  If we have learned something from Direct, we have learned that trust models are important, and that radical changes to trust models should be undertaken very carefully.

Social Services Data Capture:  Modules in Physician health IT systems are proposed in the 2015 Certification rule to become the mechanism of data capture for a great deal of VERY sensitive personally identifiable information, some of it not directly related to healthcare issues.  Gender identity, annual income, or use of social services are certainly related, but not directly applicable. While this might be useful in the context of providing many social services, the standards proposed have not been formally developed in the 2015 Certification rule with coordination with IT used with social services in mind.  I'm NOT certain that this additional requirement is something that should be added to the responsibility of healthcare providers without consideration of the other impacts it has on healthcare services.

In any case, I think we need to be very careful about how we create new criteria for health IT modules.  In the standards advisory published by ONC, a couple of these issues (Fraud investigation and much of the data that I mention with regard to social services data capture) weren't even investigated by Federal Advisory Committees.


Thursday, March 26, 2015

Too many masters in 2015 Certification

I've finally finished my review of the 2015 Certification Criteria.  As a reward I now get to read the Stage 3 Penalties Rule next.

I put together a spreadsheet containing a bunch of useful factoids from the rule.  The first tab is probably the most important.  It shows:


HeadingDescription
2015 CitationThe section of the NPRM
CriteriaThe name of the criterion
New/Revised/UnchangedWhether the criterion is new, revised, or unchanged, or whether comments are asked for.
CommentsNotes on the criterion
2015 StandardsWhat standards are referenced and where in the rule
2014 CitationWhere the former criterion that was similar to it can be found

Having completed this work, I can tell you overall, I'm not really satisfied with this rule.  For one, there are way too many references to unfinished work.  It would have been better to delay and let that work be finished, or simply not reference it this time around if it was not critical to the regulation. Unfortunately, I think ONC is trying to please too many masters on this regulation.

As a set of "Health IT Certification" requirements, it NEARLY COMPLETELY misses everyone Health IT modules supporting anyone previously excluded from Meaningful Use.  For example, while we have criteria on sending to public health, there are absolutely NO CRITERIA for public health to receive using Health IT that conforms to these standards.  This is a huge miss.  The ONLY reason we don't have a similar miss in Labs is because a Hospital EHR has to be able to transmit lab results.

Some material, such as the administrative criteria is overkill in the extreme.  Three different signatures, plus requirements for FIPS Level 2 certified encryption modules?  Really?  For a automating a part of the business that previously used copiers and fax machines and wet ink signatures (that could be applied with a stamp).  This is using a sledge-hammer to swat fleas.  There is really no accounting for physician workflows from the point of care of the patient to the point where payment is being requested.  A great deal more work is needed here before we could ever support this level of technology.  90% or more of what is needed could be done without imposing nearly such a complex set of technology requirements.

Also, while I very much welcome some of the requirements around C-CDA validation, this could have been applied very much at a sub-regulatory level.  NIST and others already have the opportunity to propose and the Secretary the authority to approve testing methods.  They need NOT be spelled out in regulation.  Having done so prevents NIST or others from developing or using better and more efficient testing methods that don't necessarily follow the patterns in the regulation.  So much for innovation and efficiency in testing if that path is continued.

    -- Keith

P.S.  In case you haven't seen it, John Halamka and Micky Tripathi have summarized both rules, in what Health IT News called "The Good, The Bad and the Ugly of Stage 3 MU".


Wednesday, March 25, 2015

Remaining 2015 Certification Criteria

I've finished looking at the certification criteria, but still have about 150 pages of more reading until I'm done with the ONC Certification Rule.

Here's what I've found in the remaining criteria:

Public Health

All the standards have been updated to more recent versions.  This shouldn't be a huge shift, but I suspect the new Immunizations guide will have some new capabilities that you want to look at.  They dropped the "Cancer Case" certification criteria from the 2014 edition in favor of a separate case reporting guide based on the IHE Structured Data Capture Work.  But for that, ONC also wants to know if we should use FHIR.  I think timetables dominate here.

The HL7 Healthcare Associated Infection Reports (you might remember this as "Hospital Acquired Infections" if you are a) old enough, and b) politically insensitive) now have a home in a criterion designed to capture information about antimicrobial use and resistance.  These specifications and this project has been around in HL7 for quite some time.

They've also added a criterion to support transmission of electronic survey data to public health using the HL7 National Health Care Surveys implementation guide.

Design and Performance

In design and performance, gratefully, numerator and denominator recording remain unchanged. 

Safety Enhanced Design (SED) gets a big makeover.  They added Demographics, Vitals Signs, Problem List, Implanted Device List, Decision Support Knowledge Artifact and Service, and Incorporation of Lab Tests and Results into the original list of ten items requiring SED.  Rather than summarize the set of changes, let me just tell you to read this section closely.

On the use of a Quality Management System, this is the pertinent quote:
For the 2015 Edition QMS criterion, we are taking that next step by not permitting health IT to be certified that has not been subject to a QMS and also requiring health IT developers to either use a recognized QMS or illustrate how the QMS they used maps to one or more QMS established by the federal government or a standards developing organization(s) (SDOs)
Basically, this means get on board with QMS.  You could get away without one previously, but now they are serious, and if you've rolled your own, you will have some work ahead of you to map to the standards.

Accessibility: There's been a push to make sure that not only is data accessible to patients in an accessible fashion, but also that the design of  EHR systems takes into account accessibility requirements for providers.  This is another section where you will want to look closely, and have your User Centered Design (UCD) folks look over your shoulder (or you over theirs).  If you don't have any UCD folks on staff, be worried.  [I'm still maintaining an A.E. Neuman pose on this section].  There's also a push to document all accessibility standards or laws that the Health IT module conforms to.  The list of standards and laws here seems like overkill ...

C-CDA testing will be toughening up (and its about time).  I think the certification criteria is a bit overboard in this area, because a lot of what they describe could be addressed in a sub-regulatory fashion in how they test C-CDA creation and display.

Application access to the common clinical data set is a huge addition in this rule.  This is the API criterion, which functionally describes what the API should do.  The closest standard we have for this is FHIR, which is where I expect this to go eventually, but ONC clearly heard that it wasn't ready yet [even though they've mentioned at least five standards that are still in the making in this rule so far]. I'm sure most EHR systems have this capability, the question is whether they want to expose it quite so far as is required by ONC.  Some of the documentation that EHR vendors have they consider to be trade secret, released only to customers under an NDA.  That situation seems likely to change if the rule goes through as currently written.  It is an interesting consideration, because elsewhere in IT, the situation is remarkably similar to the current situation in Health IT, that product APIs are often only released to licensed users of the product.

Transport Protocols

There's not much new here, although with Direct they'd like to add an Implementation Guide on Delivery Notification.  There's a bit of rework on the Edge protocols around XDR/XDM, regarding support for XDM.  The SOAP transports remain unchanged [I might guess that their maturity is showing ;-)].  On the new side, there's HPD with a separate request and response criteria, optionally utilizing Federation.

Administration

This is another new one, and frankly, a bit of a mess.  There are three separate capabilities required for signatures (are these guys signature happy or what? ... what else would you expect from auditors). There's an additional set of C-CDA templates also required supporting what is effectively attachments, although that specification has certainly received mixed reviews from the HL7 Attachments workgroup during its development.  This one needs a careful look, because maybe there will soon be an attachments rule, and my guess is that it would reference this NPRM, if it ever sees the light of day (after 15 years of waiting, I have reason to be dubious).

Thus ends my review of the criteria, there's still some 150 pages left, including the actual rule text itself.  Once I finish that, I'll have another spreadsheet to share, and then on to the Penalties rule.

   -- Keith



Tuesday, March 24, 2015

Changes to View, Download and Transmit under the 2015 MeaningfulUse Certification Criteria

This is a big one by itself, and so deserves its own post.  To be fair, they didn't change anything else in this section (Patient Engagement), but beyond Secure Messaging, there wasn't much else there beyond this one.

First of all, they updated the standard to C-CDA 2.0.  But there's a lot of additional features here:


  1. Patients need to be able to view their imaging and laboratory reports 
  2. They ask for comments on whether patients (Apps really) should have access to the API mentioned elsewhere in the rule.
  3. They add addressee to the Audit History (this is minor)
  4. They want to know if they should focus only on CCD creation (rather than any other kind of document allowed in C-CDA).
  5. They ask again about the maturity of an as yet unpublished specification from HL7 (Data Provenance)... you can guess my answer on that one.  
  6. They dropped specification of a Clinical Summary (mostly I think it moved to the Penalties Rule*)
  7. On Transmit, they wonder if adding the Trust Bundle Distribution Specification is worth doing.
  8. Finally, they wonder if they should add a WCAG 2.0 Level AA requirement (they are already at Level A)

Some feedback on these: First, with regard to access to other reports, I'm all for it, but I would suggest these need not be conformant YET to any published specifications.  I'd be OK with some optional criteria around this (e.g., Diagnostic Imaging Report in C-CDA, or use of XD-LAB for Laboratory results), but at the moment, there are plenty of these that simply aren't available in this format.  Patients need the data, let's not get in their way.

App access to an API is basically what Blue Button Plus Pull was about, and I think that would be a good place to start.  They could build on FHIR and Mobile Access to Health Documents, but given FHIR's readiness, I think a functional requirement is sufficient.  The industry will likely choose FHIR and MHD without any further prompting from ONC.  I think document access is the right place to start.

On the whole CCD question, my answer is thus: Vendors who haven't figured out that it is the section templates that they need to worry about, and NOT the document templates are few and far between.

DPROV is clearly not mature, having not yet even been born by HL7 as a DSTU.  That's still out in HL7 for reconciliation, although they don't note that in the NPRM as they did with everything else.  I still have comments that have yet to be reconciled on that one (now scheduled for early April), and the major delay for me has simply been conflicting schedules.  As I said in a tweet, the metadata on that project should tell you something about its provenance.

On dropping the clinical summary, I think some functional work is necessary here, but unfortunately, the HL7 Pertinent and Relevant project is still being developed and has yet to be approved as a project (we are targeting before HIMSS).

I'll let John Moehrke take on the Trust Bundle stuff, that's not up my alley.

With regard to Level AA, I'm not so sure about that, mostly because of mobile.  Level AA can be challenging in a desktop browser.  With mobile, it could be more so.  I have to think about that one.

   -- Keith

* I used to call the CMS rule the Incentives Rule, but that no longer applies in most cases.

More on MeaningfulUse Certification: Quality and Security

Quality Reporting

For quality measures, the challenge is that the standards that folks have been working on just aren't ready yet.  This is largely in part due to the whole Health eDecisions/Health Quality Measure Format incompatibility created a couple of years ago.  A self-inflicted wound if ever there was one, but one that is healing, but not fully healed yet.  I'm not sure how to respond to this one yet.  I think we stay the course, but one of the things I'm looking for this cycle is whether provisions have been made to pilot new technology.  That will show up in the Incentives rule (should I be calling it the penalties rule).

Throughout this section, one change you will see is that:
... when a Health IT Module is presented for certification to this criterion, we would expect that testing of the Health IT Module would include demonstration of a user’s ability to ____ without subsequent health IT developer assistance beyond normal orientation/training.
This basically is saying that users have to be able to execute the functions that the module is certified to without having to call on the vendor for support.

Security

On security, you can rest easy with regard to the certification criteria, as they remain unchanged. They do ask for comment about when SHA-2 (SHA-256 for example) should be phased in and how.


What? Me Worry? Care Coordination in MeaningfulUse

I've just made it past the Care Coordination section of the Meaningful Use Certification NPRM.  Clearly I'm picking up speed, and hope to be done the rest of the rule today, but thought I'd share what I've learned thus far:

Not to Worry about:

There isn't a thing that you shouldn't worry about some in this section, unless of course your name is Alfred E. Neuman.

Worry about a little:

Transmission of Laboratory Test Reports, and incorporation of Laboratory Test Results both have updated standards.  This isn't really a huge lift, but you will need to pay some attention to the new standards.

Worry about:

Data Segmentation for Privacy is a new requirement, so even though it is fairly easy (tag documents as being more restricted for example), you should pay a bit more attention to this.  

If you are one of those called out on Data Portability for making it hard to use or configure by the customer, you have some work ahead of you, otherwise you'll be just fine.  I'm not too worried about this one.

For Reconciliation, they'll be tightening up the testing.  This is long overdue in my opinion.

Worry about a lot:

There's a technical term for the quantity of change in the Transitions of Care requirements that is NSFW.  We call it a ****-ton in software engineering terms.

First, there's a version change in C-CDA which adds a number of new document types.  That alone is a big effort, but not as big as before the template versioning problem got resolved.

Next there's some stuff about validation checking CCDA documents.  Now, if you haven't been checking whether inputs to your EHR system coming from outside the user organization are valid to begin with, you have quite a bit to worry about (I personally am not too worried about this). However, this is going to involve some product change in a few places because ONC will now be looking over your shoulder at how you do this.

Can your product handle an XDM file in a Direct communication?  If not, you need to worry about this.

Finally, you need to make sure that identities you communicate are well suited for patient matching down the road.

These last two items are small in and of themselves, but they are all wrapped up in one VERY BIG certification criterion.

e-Prescribing is another area where there's a boat-load of changes.  In addition to requiring NEWRX messages, ONC is proposing the testing of five other transactions in NCPDP Script 10.6: RXCHG/CHGRES, CANRX/CANRES, REFREQ/REFRES, RXFILL and RXHREQ/RXHRES. 

Also, they have proposed the use of structured sigs in prescriptions.  No more dumb text which led to this mess in my daughter's prescription.

Lastly, there are Care Plans, which is another completely new thing in C-CDA, and has some serious ramifications.  I'm all for this one, but as a new requirement, you'll need to examine it deeply.



MeaningfulUse Objectives-Measures-Certification Criteria-Standards Cross Walk

One of the things I love about the Meaningful Use NPRM's is how people across the industry share the load of analyzing the rule. Last week Corey Spears gave us all links to the bookmarked PDFs. Yesterday evening, Hans Buitendijk (formerly of Siemens and now Cerner) sent me his spreadsheet, which you can find here.

     Keith



Monday, March 23, 2015

What to worry about in the MeaningfulUse 2015 Certification NPRMs

After two weeks of 12-hour a day training (which is why this blog has been uncharacteristically quiet), I was awarded Friday by ONC with way to many pages to read, just like everyone else.  I'm barely 25% done on the Certification rule, but many have already asked for my views and observations.  Here is what I know so far:

There are 67 certification criteria, up 18 criteria from 49 last cycle.  The criteria has been rewritten to apply all of Health IT, not just EHR systems.

The Clinical Criteria

Within the clinical criteria sub-section 170.315(a) there are 23 criteria, 7 are unchanged, 11 revised, and 5 new criteria.

Things you don't have to worry about: CPOE for Medications and Imaging, Medication and Medication Allergy Lists, Imaging Results, Patient List Creation, and Electronic Medication Administration Records.

After updating your vocabulary to the new standards, you also don't have to worry about these:
Demographics, Problem Lists, Smoking Status, and Family Health History.

Now, start worrying, but not too much yet:


Simple Stuff

Vital Signs just got a little more complicated, but for anyone who has been following HITSP, IHE, CCD, C32 or C-CDA specifications, these are pretty simple upgrades.  There are a few new "vital sign" codes that can be applied for dealing with BMI, or oxygen saturation, but for the most part, this is pretty straightforward stuff.

Drug/Drug and Drug Allergy and Intolerance checking also got a bit more complex, in that now you are expected to record what providers do with those alerts.  If you haven't instrumented them already, you will be expected to do so.  This is also fairly simple and obvious.

CDS adds the same requirement to record what providers do in response to an intervention, again, not a big lift.

On requesting patient specific education resources, a new requirement that they be able to be requested in the patient's preferred language has been added.


Moderately Challenging

Among the moderately challenging requirements, the following have been added or revised:

Lab CPOE is about to get harder, and easier.  There are new standards to apply for the compendium, and the order.  In general though, this one is a wash, PROVIDED we can get labs (which have NO incentives to use MU standards) to start using them.  This will be work, but also have value for everyone under that proviso.  

If you don't already support the HL7 Pedigree standard, the new rule splits it out as a separate criterion.  It won't be as hard as say, the C32 or the C-CDA, but it will be challenging if you have to do it to support the CMS rule for your customers (I haven't even cracked that one open yet, so I don't know what the ramifications are for that).


Difficult

They've changed capturing Advance Directives to capturing details about other documents, such as birthing plans.  The rationale sounds good, but I'm not sure the two really want to work the same way, especially given the new care planning work in C-CDA Release 2.0*.

Drug Formulary and Drug List Checks will also be on the more difficult side if you haven't already adopted the NCPDP Formulary and Benefit Standard v3.0 standard that was part of the voluntary criteria.

Populating the Implantable device list is probably going to include a whole new set of user interfaces for folks.  I know of some, but not many EHR systems that presently capture this data.  Of course, I would expect most are all able to be configured to capture it, but then when you add the measures for whether it was captured for patients, it gets a bit trickier.

The big mess is in the capture of social, psychological and behavioral data.  I don't doubt the value of this as specified in the rule, but it begins to become invasive with respect to patient privacy.  Not only will this involve a bunch of new data capture screens, but also requires enhanced security due to the more sensitive nature of some of this data.  It also begs the question of how much data SHOULD be required under the certification and incentive rules.

Adoption of the CDS Knowledge Artifact and Service standards is also going to be challenging. There's still a lot of work being done to clean up and harmonize the specifications.

Overall, I long for the day when a Certification rule adopts no standard that is still in its infancy. Granted, we have a long way to go before we get there, but we are still in that period of early growth where every day brings new changes.  At some point, I'd love to get this program to a point where the improvement is more evolutionary than revolutionary.  I'm not arguing the need for revolution, BTW, just wishing that we didn't need so much of it at once.

   -- Keith

P.S. There will be more when I've had a chance to read another hundred pages or so...

* Note that while I think C-CDA Release 2.0 is also going to be challenging, I haven't really analyzed all the details for that yet, since it is in the Care Coordination Section.

Friday, March 20, 2015

The new phone books are here...

Just in time to ruin my weekend....
------
HHS Issues Proposed Rules for Stage 3 of the Medicaid and Medicare EHR Incentive Programs and the 2015 Edition of Health Information Technology

 

Today, the Department of Health and Human Services’ (HHS) Centers for Medicare & Medicaid Services (CMS) issued a proposed rule for Stage 3 of the Medicare and Medicaid Electronic Health Record (EHR) Incentive Programs. Separately, the Office of the National Coordinator for Health Information Technology (ONC) issued a proposed rule for the 2015 Edition of Health Information Technology (Health IT).

 

EHR Incentive Programs Stage 3 Proposed Rule

 

The Stage 3 proposed rule focuses on making the EHR Incentive programs more flexible, simplifying and reducing burden of providers participating in the program, driving the interoperability of health IT, and improving patient outcomes.

 

The CMS Stage 3 Meaningful Use proposed rule includes proposals that would:

 

  • Realign the reporting period into a single one for all providers starting in 2017 (hospitals will participate on the calendar year instead of the fiscal year);
  • Allow providers the option to start Stage 3 of meaningful use in either 2017 or 2018 (required in 2018), which gives providers an extra year to start than under current regulation;
  • Reduce the overall number of objectives to eight in order to focus on the advanced use of EHRs;
  • Remove measures that are redundant or obtained wide-spread adoption;
  • Align clinical quality measure reporting with other CMS programs; and
  • Propose the use of application program interfaces (APIs) that could enable the development of new functionalities to build bridges across systems and provide increased data access.

 The Stage 3 proposed rule’s scope is generally limited to the requirements and criteria for meaningful use in 2017 and subsequent years. CMS is considering additional changes to meaningful use beginning in 2015 through separate rulemaking.

 

2015 Edition Health IT Proposed Rule

 

The ONC 2015 Edition proposed rule builds on the foundation established with the 2011 and 2014 Editions.  It proposes to adopt standards and certification criteria designed to foster innovation, open new market opportunities, provide more choices to the care community for electronic health information exchange, and support ONC’s vision for interoperability.

Specifically, the 2015 Edition proposed rule would:

·         Enable a more flexible certification program that supports developer innovation and focuses on interoperability;

·         Adopt new and updated vocabulary and content standards for the structured recording and exchange of electronic health information;

·         Facilitate the accessibility and exchange of electronic health information by including enhanced data portability, transitions of care, and application programming interface (API) capabilities as part of the 2015 Edition Base EHR definition;

·         Adopt standards to address health disparities, including standards for the collection of social, psychological, and behavioral data, and for the accessibility of health IT;

·         Prioritize the privacy and security of data a priority, by ensuring relevant privacy and security capabilities and by addressing the exchange of electronic sensitive health information  through the Data Segmentation for Privacy standard;

·         Improve patient safety by applying enhanced user-center design principles to health IT, enhancing patient matching, requiring relevant electronic health information to be exchanged (e.g., Unique Device Identifiers), improving the surveillance of certified health IT, and making more information about certified products publicly available and accessible; and

·         Increase the reliability and transparency of certified health IT through surveillance and disclosure requirements.

 

A press release will be available at:  http://www.hhs.gov/news. A Consumer Fact Sheet will be available at:  http://healthit.gov/newsroom and a Technical Fact Sheet for the 2015 Edition Proposed Rule will be available at:  http://healthit.gov/newsroom.

The Stage 3 and 2015 Edition proposed rules may be viewed at:  https://www.federalregister.gov/public-inspection.

The Draft 2015 Edition Certification Test Procedures will also be published and may be viewed at http://healthit.gov/2015-Edition-Certification.

 

More information the EHR Incentive Programs is available on the CMS website at http://www.cms.gov/Regulations-and-Guidance/Legislation/EHRIncentivePrograms/index.html.

More information on ONC’s editions of certification criteria can be found at http://www.healthit.gov/policy-researchers-implementers/standards-and-certification-regulations.

If you have any questions regarding the Stage 3 proposed rule, please contact the CMS Office of Legislation.  Please contact Blair Hedgepeth, ONC Legislative Liaison at blair.hedgepeth@hhs.gov with any questions regarding the 2015 Edition proposed rule.  Thank you.


Tuesday, January 20, 2015

Is Your CCDA Document Relevant?

One of the challenges with Meaningful Use has to do with the way that it started; first with one kind of document, the CCD (using the HITSP C32 specification), later migrating to CCDA which supported multiple document types.  Meaningful Use never gave any guidance on which CCDA document types to use for different purposes, and in fact, defined content based on a combination of document types found in CCDA.  As a result, most folks are still using CCD, which really is designed to be a general summary of care.  But physicians generate other kinds of documents during routine care, such as a history and physical note, or a consult note, or an imaging report.

Because the 2011 edition required use of CCD, but these weren't related to what physicians were generating, the documents were automatically generated. And since they were automatically generated, there's no physician in the loop to determine what is relevant and pertinent.  Vendors have built interfaces to make it possible for them to select relevant and pertinent, but that takes time in the physician workflow.  So vendors get told to automate the generation process, and depending on how they do that, the result is often less than ideal.

By about 65 pages.

I've talked about this problem previously, and at the time, it seemed to me that the solution should have been obvious: Use the physician's existing documentation process to select what is pertinent and relevant.

But the evolution of Meaningful Use from a document that physicians don't generate to a collection of documents which they might use assumed a level of integration with physician workflows that simply wasn't allowed for by Meaningful Use timelines.  Basically the setup of clinical documentation workflows is something that is usually done during an initial EHR installation.  It isn't redone when the system gets upgraded, because that is usually a non-essential disruption for the provider.  But that is what it would take to use the new document types.  Now, that process will likely occur over time as hospitals and providers update their systems to improve their workflows, but in the interim, it leaves automatically generated CCD 1.1 as the documents that get exchanged for Meaningful Use.

Now we get into the disconnect.  Most EHR developers that I've talked to know that clinicians are the best judge of what is pertinent and relevant content to be exchanged.  This results in the choice of what is relevant to be set up as system configuration parameters.  Lawyers and HIT administrators (and sometimes physicians), tend to err on the side of caution when trying to figure out what should be sent to a receiving system in this configuration.

Which results in a 70 page "summary" of the patient data, which is at least 65 pages too long for anyone to read (and probably closer to 68 pages too long for the average physician).  As a result, when these documents get created and sent, a physician will look at them once or twice, and then decide they aren't useful and never look at them again.

How do we fix this?  I ran into a similar challenge over the last year and the answer that I came up with then was to talk to clinicians about what the right rules were for limiting the data that would be provided.  There were three sets of limits, time based, event based, and state based limits.

Information about active issues needs to presented regardless of time (assuming appropriate management of active and resolved in the provider's workflow).  This would include problems (conditions), allergies, and any current (active) medication.

Event based limits are based on recent care, e.g., activities done in the last encounter.  So any problem or allergy marked as resolved in the last encounter would also show up so that you could see recent changes in patient state.  Additionally, any diagnostic tests and/or results related to that last ambulatory visit would also be included (inpatient stays need a slightly different approach because of volume).  Finally, the most recent vital signs from the encounter should be reported.

Time based limits include dealing with stuff that has happened in recent history.  For this, for an adult patient, you probably want the last year's immunization history.  You likely want to know about any problems whether they were active or resolved in the patient's recent history (we wound up equating recent history to the last month).

There are certain exceptions that may need to be added, for example, for pediatric immunizations you might extend history to a longer period, but in an age dependent way.

HL7 Structured documents has agreed to begin working on a project in which we will work with clinicians, and reach out to various medical professional societies to help define what constitutes a reasonable set of limits for filtering relevant data.  I'm thinking this would be an informative document which HL7 would publish and which we would also promote through the various professional societies collaborating on this project.

So, I think I was both wrong and right in my original post on this topic.  It is impertinent for a developer or a system to decide what is relevant, but,  it is possible, with the participation of clinicians, to develop guidance that system implementers could use to configure the filter of what should be considered relevant.  And my advice to system designers is that while you might want to supply a good set of defaults, you should always let the clinician override what the system selects.


Wednesday, December 3, 2014

Bones or Monty Python?

A couple of weeks ago, Bob Watcher wrote: Meaningful Use. Born, 2009, Died, 2014? John Halamka suggested we need to Declare Victory for Meaningful Use (see item #5) by 2016 even earlier this year.

I'm not so sure Meaningful Use is dead.  It's pretty clear its a program in transition, but that writing was already on the wall when there was a transition from payments (2014) to penalties (2015).  I fully expect to have another 500 pages to read this holiday season.

How about you? Who's right? Bones or the old coot from Monty Python?