Acronyms are a way of life for a Standards Geek. These "short-form" names are an insider's code, almost as incomprehensible as 1337. CDA, CCR, CCD, XDS-MS, C32, C48, C80, C83, XPHR, GreenCDA, CCDA (an Acronym first coined here by Wes Rishel), et cetera. For the average implementer, lack of knowledge about acronyms leads to miscommunication of requirements, subsequently resulting in incorrect implementation and later rework. It gets even more challenging because many of these have several meanings. The CCR is a data set and an XML Schema. A CCR is an XML document that conforms to the XML Schema, but it can also be an implementation that conforms to the data set (e.g., The CCD is a CCR).
I spend a good deal of time with implementers who ask questions about CCD trying to be sure what they really mean, because I'm aware that most people in the US who are asking questions about "CCD" are really asking questions about the Meaningful Use requirements laid on top of the HITSP C32. Sometimes the question really does get back to the HL7 CCD specification, but more often than not, it doesn't.
This post from mid-2010 shows 50 different specifications. Each one has it's own acronym and has several different kinds of relationships with at least two or more others with only ONE exception (CDA). I won't go into why we (geeks) use acronyms. Tone Southerland (a standards geek colleague in IHE PCC) already explains that in this blog post. What I'm going to try to address in this post is how an implementer is to cope.
So, here are the cliff notes. If you are an implementer, you should study this, as there will be a test.
CDA - Clinical Document Architecture. An HL7 standard describing the XML format of clinical documents. It has also been approved by ANSI and ISO. Currently in release 2.0, with work on release 3.0.
CCDA - CDA Consolidation Guide. An HL7 Draft Standard for Trial Use consolidating the past work of HL7, Health Story, IHE, and HITSP into one consolidated guide. The acronym was first coined by Wes Rishel. Most participants call it the "Consolidation Guide".
CCR - Continuity of Care Record. An ASTM standard data-set for information to exchange between systems supporting to support continuity of care. It is published with an accompanying adjunct that is the XML Schema created by ASTM that conforms to that standard. The format specified in the adjunct competes with the HL7 CDA.
CCD - Continuity of Care Document (Release 1.0). An HL7 Informative document harmonizing the ASTM CCR and the HL7 CDA. A CCD is a CCR, but uses the HL7 CDA standard to represent the data. It has now been superseded by the CCD 1.1 found in CCDA.
XDS-MS - Cross Enterprise Sharing of Medical Summaries. An IHE profile (implementation guide) from the IHE Patient Care Coordination domain and is part of the PCC Technical Framework. It was originally based on the CRS 1.0, but was later changed to use the CCD.
CRS - Care Record Summary (Release 1.0). An informative document from HL7 based on the CDA, and one of the intellectual ancestors of the CCD. In competition with the CCR at the time of publication, but now superseded by release 2.0, and the CCDA.
XPHR - Exchange of Personal Health Records. An IHE profile (implementation guide) from the IHE Patient Care Coordination Technical Framework. It describes and further specifies how to use the CCD to exchnage information between PHR systems and EHR systems.
C32 - Summary Documents Using HL7 Continuity of Care Document. A specification published by ANSI/HITSP that further codifies how to use the CCD for the US. Originally based directly on the HL7 CCD, it was later adapted to use the IHE XPHR profile. However, confusion in interpretation of this specification by industry certifiers has led to conformance to the IHE PCC Technical Framework, but not necessarily XPHR directly. The C32 makes use of the HITSP C80 and C83 specifications.
MU Stage 1 - Meaningful Use Stage 1. A set of regulatory requirements for certification of EHR Systems that enable providers to obtain incentive payments from the federal government. In addition to requiring support for both the CCR and CCD, it provides additional requirements over and above the HITSP C32 which result in yet further confusion about what a C32 is.
C48 - Encounter Document Using IHE Medical Summary. A HITSP specification for encounter summaries based on the IHE XDS-MS.
C83 - CDA Content Modules Component. A HITSP specification containing almost all CDA Section and Entry templates used in HITSP CDA based implementation guides. The only real exception is the HITSP C37 Lab Report document based on the IHE XD-LAB profile.
C80 - Clinical Document and Message Terminology. A HITSP specification containing vocabulary requirements for almost all HITSP specifications. These are referenced by C83.
C37 - Lab Report Document. A HITSP specification for lab reports using CDA, based on the IHE XD-LAB profile.
XD-LAB - Sharing Laboratory Reports. An IHE Profile from the IHE Laboratory Technical Framework for laboratory reports represented using CDA.
Showing posts with label HITSP. Show all posts
Showing posts with label HITSP. Show all posts
Thursday, December 1, 2011
Friday, October 28, 2011
Half of ACO Quality Measures are in MeaningfulUse
I was doing a review of the ACO Quality Measures yesterday. One thing I noted was that at least half of them are also in Meaningful Use. The cool thing about that is that this team has already reported that most MU measures can be computed from the HITSP C32 with the addition of procedures section, and that nearly all can be addressed by adding smoking status and vitals (see pages 4-6 of their paper).
What about the other half? Well, six of them come from what will now be a CMS supported survey, three of them come from claims data, and another one comes from Meaningful Use attestation reports. So, of the remainder, what isn't in Meaningful Use Stage 1, and can it be computed from the HITSP C32?
These are the remaining measures:
What about the other half? Well, six of them come from what will now be a CMS supported survey, three of them come from claims data, and another one comes from Meaningful Use attestation reports. So, of the remainder, what isn't in Meaningful Use Stage 1, and can it be computed from the HITSP C32?
These are the remaining measures:
- Medication Reconciliation at Discharge (NQF #97)
- Fall Risk Screening (NQF #101)
- Depression Screening (NQF #418)
- Proportion of Adults 18+ who had their Blood Pressure Measured within the preceding 2 years (CMS)
- Diabetes Measures (NQF #729
- Ischemic Vascular Disease (IVD): Complete Lipid Profile and LDL Control (NQF #75)
- Treatment for CAD w/ Diabetes/LVSD (NQF #66)
Looking at each of these:
Fall Risk (#2) and Depression (#3) screening assessment scores can be recorded in the HITSP C32 Results section. So, if you find an assessment result, you can tell that these have been done.
The diabetes measures (#5) are from the MN Community Measurement instrument. These account for five separate measures in the ACO rule and are very simple to compute from CCD medications, results, vital signs or social history (for tobacco use) sections:
- HgA1C < 8
- LDL < 100
- BP < 140/90
- Tobacco Non-Use
- Aspirin Use
The IVD (#6) and CAD (#7) measures can also be readily computed, as they are very similar to other computable results in Meaningful Use stage 1.
That just leaves #1, Medication Reconciliation on discharge. Because the CCD is not a discharge summary, you'd really want to look at a different document to compute that measure. But if you did open up a discharge summary, and found one of the required entries of the IHE RECON profile, you could be assured that medication reconciliation was performed at discharge.
So, half of ACO measures are meaningful use measures, and you should be able to compute nearly all of the the other half from the standards already required for Meaningful Use stage 1. And it could even get better under stage 2 when we have other documents supported for Transitions of Care.

Thursday, October 27, 2011
CDA Consolidation: It's a Library, not just a Book
We've had several discussions on the CDA Consolidation guide project on one of my negatives. As originally stated, I was proposing that we remove the required LOINC code for CCD 1.1 (yes, there will be a new version of the CCD when the CDA Consolidation guide is done). The rationale for this suggestion was that we want there to be a way to say: "It's a CCD", without fixing the document type.
As the discussion went on, it evolved into there existing a template identifier that indicates "This document conforms to all applicable sections and entries (and documents), found in the CDA Consolidation guide".
This feature was already present in the HITSP C83 specification, and is reproduced below. As such, it is certainly within the scope of the HL7 project to ensure that this feature is reconciled along with the IHE and HL7 guides.
What is the point of it?
The main point is that the CDA Consolidation guide, like the CCD, IHE PCC Technical Framework and HITSP C83 specifications that it harmonizes, is a library of documents, sections and entries. In IHE we've found that the IHE PCC Technical Framework is more widely used as a library of sections and entries than the individual document templates specified within it. The IHE section and entry templates are presently in use in national projects in the US, Europe, Japan and China. The same is true for CCD template (there are over 20 implementation guides using CCD templates). We can certainly expect, based on that experience that the same will also be true for the CDA Consolidation guide. The HITSP guide not only anticipated this behavior based on prior experience, but also promoted it through the above conformance rules.
What are the benefits of asserting this template identifier?
Suppose that you have developed an application that understands the CDA Consolidation guide, and gathers information from appropriate sections on problems, medications, and allergies. Now, you want to use this application, but someone has determined that they need a new document type not covered by the guide. As an example, let's look at an assessment of health and functional status for long term care use. This clearly isn't covered by the current set of documents in the CDA Consolidation guide.
But, if someone were to create a new implementation guide, and use the CDA Consolidation guide sections and entries, my application could take advantage of that fact. There is a major concern here, which is a potential impact on patient safety. Suppose my application uses the information in this document, specifically on problems, medications, and allergies, to provide some clinical decision support for the patient assessed in the document. Suppose also that the creators of that assessment instrument (a CDA implementation guide), decided that they didn't like the way that CDA Consolidation dealt with allergies, and so they used an incompatible model. What could happen? Well, if you didn't know that they used a different model for allergies, when you tried to extract the allergy information, your application would either not find it, or not find all the details recorded in the same way as they had been recorded according to the consolidation guide. As an end result, you wouldn't have the allergy information, and could produce incorrect, perhaps even dangerous results.
Now, how can you tell that they've used templates you understand. In this particular example, you'd make a list of the templates you need, and then go check to make sure that the document incorporated them. This particular example is deliberately simplified, so maybe you only need the handful of sections and entries related to problems, meds and allergies (there's at least a dozen of these). Even having checked that, you really don't have any assurance that they haven't added another section that does things differently in a way that you don't understand.
What the CDA Consolidation template identifier would do is tell you that the document has done things the CDA Consolidation guide way for everything that overlaps in anyway with what already exists. That means that it doesn't record the same information present and described somewhere in the guide in a way that it NOT compatible with the guide.
This gives the receiving system a statement of assurance that says, if CDA Consolidation guide did it this way, this document does it this way as well. That means that the receiving system has less to worry about with respect to information being recorded differently from what it already understands.
This is exactly the rationale that HITSP used when adding these conformance statements to the C83 specification in support of the Clinical Note Details use case. And in fact, someone did create a guide just like the one I just described that conformed to the HITSP template for C83. It was the CARE-SET implementation guide used in the C-HIEP demonstration project. And guess what, that project also used MDHT.
Granted, just because someone asserts the template identifier, it doesn't mean that you can simply assume that what they've done is correct. You also have to be able to test conformance to it.
How can you test this?
Some of the opposition seems to come from "we don't know how to automate the test." There are assertions in the CDA Consolidation guide that have implications, and there are some unstated assumptions that may need to be made more explicit. If the section template id is X, then the LOINC code for the section must be Y. In most cases for these documents, there should be only one section of that type, so:
So, you can detect non-conforming sections and entries where these kinds of assertions (and assumptions) are present. You can also detect non-conforming entries with similar constraints on code (or other attributes) or detect missing entries from sections. You can also identify specific entry classes that do not conform to template identifiers in the guide for inspection to see whether or not they overlap.
One of the challenges here is figuring out how to create the appropriate tests based on the data that is used to generate the guide. This may be a technical challenge, but just because there is a technical challenge shouldn't be an impediment to implementing the idea. It's certainly feasible. The MDHT project managed it (see slide 8) for C-HIEP.
How does this benefit implementation guide and standards developers?
A guide that requires the assertion of the Consolidation template identifier in instances is itself asserting that it doesn't doesn't conflict with the CDA Consolidation guide. That means that it, and any additional templates it creates would be more easily considered for inclusion into the next edition of the consolidation guide. A guide that doesn't do this requires a deeper look for gaps and overlaps. It also means that when such a guide is reviewed and approved, reviewers can point out inconsistencies not just as potential problems, but rather as implementation guide errors.
How this simplifies creation of other guides?
All of the rules, all the logic, all the consistency implied in the guide is asserted in one little statement. If, as a CDA implementation guide creator, I am ready to trust in the CDA Consolidation guide, then I can turn my attention to other things that guide doesn't support. This is extremely powerful. You can adopt hundreds of pages of specification, and avoid countless hours of struggle, and there's even a way to say you did just that. If we want to make it easy to create implementation guides (e.g., using tools like MDHT) to meet other use cases, this is the kind of thing that we need to consider.
I've been through this process not once, not twice, but many times. In IHE adopting from HL7 CCD, in HL7 adopting from IHE PCC, in HITSP adopting both, and back again in HL7 with the consolidation guide. If we want "one ring to bind them", it needs to have a name, and I need to be be able to use it meaningfully. This would be extremely important for IHE adoption, because we want to ensure consistency. IHE already has document content that isn't included in the CDA Consolidation guide. How would we be able to assert consistency with it?
What does optional or recommended really mean?
A guide that asserts the Consolidation template identifier is stating that it is doing things consistently with what the guide indicates. If the guide says that severity is recorded in this way, and the instance record severity differently, and the severity assessment is optional, has the guide conformed? While the instance might conform to the allowed model, it really has failed to follow the intent of the guide. The guide says to record severity this way, and the instance didn't. This is an incompatibility that would later need to be resolved if the new guide were "brought in" to the CDA Consolidation guide.
It's a brand, not just a guide!
This is my last rationale for inclusion of this, and probably the weakest from a technical perspective, but strongest from an implementation perspective. As HL7 learned from developing the CCD, everybody wanted to be able to call everything a CCD, but not everything was. This gives HL7 something that allows everybody to use CDA Consolidation, even when it doesn't have the exact document they need, and still claim conformance to the guide.
As the discussion went on, it evolved into there existing a template identifier that indicates "This document conforms to all applicable sections and entries (and documents), found in the CDA Consolidation guide".
This feature was already present in the HITSP C83 specification, and is reproduced below. As such, it is certainly within the scope of the HL7 project to ensure that this feature is reconciled along with the IHE and HL7 guides.
Please note that the following constraints have been added to support the creation of structured documents using the templates defined in this section. The last two constraints are to ensure that a CDA document conforms to the HITSP defined sections and entities where these entries are available. If HITSP has not created an appropriate entry or section, the CDA document MAY include those.
C83-[CDA-10] CDA document instances that adhere to the specifications for the sections and entries defined within this specification MAY declare their conformance to these constraints by including <templateId> element with a value of 2.16.840.1.113883.3.88.11.83.1 in the root attribute and no extension.
C83-[CDA-11] Conforming CDA document instances SHALL conform to the HITSP defined sections* where available
C83-[CDA-12] Conforming CDA document instances SHALL conform to the HITSP defined entries** for clinical statements where available
* If the intent of the section is to capture information that could be captured in an existing HITSP section, the section shall conform to the HITSP defined section (although it may be further constrained).There are a couple of key questions around this proposal:
**If the intent of the entry (clinical statement) is to capture information that could be captured in an existing HITSP entry, the entry shall conform to the HITSP defined entry (although it may be further constrained).
What is the point of it?
The main point is that the CDA Consolidation guide, like the CCD, IHE PCC Technical Framework and HITSP C83 specifications that it harmonizes, is a library of documents, sections and entries. In IHE we've found that the IHE PCC Technical Framework is more widely used as a library of sections and entries than the individual document templates specified within it. The IHE section and entry templates are presently in use in national projects in the US, Europe, Japan and China. The same is true for CCD template (there are over 20 implementation guides using CCD templates). We can certainly expect, based on that experience that the same will also be true for the CDA Consolidation guide. The HITSP guide not only anticipated this behavior based on prior experience, but also promoted it through the above conformance rules.
What are the benefits of asserting this template identifier?
Suppose that you have developed an application that understands the CDA Consolidation guide, and gathers information from appropriate sections on problems, medications, and allergies. Now, you want to use this application, but someone has determined that they need a new document type not covered by the guide. As an example, let's look at an assessment of health and functional status for long term care use. This clearly isn't covered by the current set of documents in the CDA Consolidation guide.
But, if someone were to create a new implementation guide, and use the CDA Consolidation guide sections and entries, my application could take advantage of that fact. There is a major concern here, which is a potential impact on patient safety. Suppose my application uses the information in this document, specifically on problems, medications, and allergies, to provide some clinical decision support for the patient assessed in the document. Suppose also that the creators of that assessment instrument (a CDA implementation guide), decided that they didn't like the way that CDA Consolidation dealt with allergies, and so they used an incompatible model. What could happen? Well, if you didn't know that they used a different model for allergies, when you tried to extract the allergy information, your application would either not find it, or not find all the details recorded in the same way as they had been recorded according to the consolidation guide. As an end result, you wouldn't have the allergy information, and could produce incorrect, perhaps even dangerous results.
Now, how can you tell that they've used templates you understand. In this particular example, you'd make a list of the templates you need, and then go check to make sure that the document incorporated them. This particular example is deliberately simplified, so maybe you only need the handful of sections and entries related to problems, meds and allergies (there's at least a dozen of these). Even having checked that, you really don't have any assurance that they haven't added another section that does things differently in a way that you don't understand.
What the CDA Consolidation template identifier would do is tell you that the document has done things the CDA Consolidation guide way for everything that overlaps in anyway with what already exists. That means that it doesn't record the same information present and described somewhere in the guide in a way that it NOT compatible with the guide.
This gives the receiving system a statement of assurance that says, if CDA Consolidation guide did it this way, this document does it this way as well. That means that the receiving system has less to worry about with respect to information being recorded differently from what it already understands.
This is exactly the rationale that HITSP used when adding these conformance statements to the C83 specification in support of the Clinical Note Details use case. And in fact, someone did create a guide just like the one I just described that conformed to the HITSP template for C83. It was the CARE-SET implementation guide used in the C-HIEP demonstration project. And guess what, that project also used MDHT.
Granted, just because someone asserts the template identifier, it doesn't mean that you can simply assume that what they've done is correct. You also have to be able to test conformance to it.
How can you test this?
Some of the opposition seems to come from "we don't know how to automate the test." There are assertions in the CDA Consolidation guide that have implications, and there are some unstated assumptions that may need to be made more explicit. If the section template id is X, then the LOINC code for the section must be Y. In most cases for these documents, there should be only one section of that type, so:
- X -> Y (template id X implies LOINC code Y)
- |Y| = 1 (there shall only be one occurence of LOINC code Y)
- |Y| !-> X -> (|Y| > 1) (if Y does not imply X, then there could be more than one section with LOINC code of Y)
- Thus, Y -> X (so, in a conforming instance, if the LOINC code is Y, the template ID must be X)
So, you can detect non-conforming sections and entries where these kinds of assertions (and assumptions) are present. You can also detect non-conforming entries with similar constraints on code (or other attributes) or detect missing entries from sections. You can also identify specific entry classes that do not conform to template identifiers in the guide for inspection to see whether or not they overlap.
One of the challenges here is figuring out how to create the appropriate tests based on the data that is used to generate the guide. This may be a technical challenge, but just because there is a technical challenge shouldn't be an impediment to implementing the idea. It's certainly feasible. The MDHT project managed it (see slide 8) for C-HIEP.
How does this benefit implementation guide and standards developers?
A guide that requires the assertion of the Consolidation template identifier in instances is itself asserting that it doesn't doesn't conflict with the CDA Consolidation guide. That means that it, and any additional templates it creates would be more easily considered for inclusion into the next edition of the consolidation guide. A guide that doesn't do this requires a deeper look for gaps and overlaps. It also means that when such a guide is reviewed and approved, reviewers can point out inconsistencies not just as potential problems, but rather as implementation guide errors.
How this simplifies creation of other guides?
With one assertion, I can adopt all the rules in the CDA Consolidation guide. Essentially, I've declared:
import org.hl7.sdwg.CDAConsolidation.*; (for Java developers)
using org.hl7.sdwg.CDAConsolidation; (for C# developers)
All of the rules, all the logic, all the consistency implied in the guide is asserted in one little statement. If, as a CDA implementation guide creator, I am ready to trust in the CDA Consolidation guide, then I can turn my attention to other things that guide doesn't support. This is extremely powerful. You can adopt hundreds of pages of specification, and avoid countless hours of struggle, and there's even a way to say you did just that. If we want to make it easy to create implementation guides (e.g., using tools like MDHT) to meet other use cases, this is the kind of thing that we need to consider.
I've been through this process not once, not twice, but many times. In IHE adopting from HL7 CCD, in HL7 adopting from IHE PCC, in HITSP adopting both, and back again in HL7 with the consolidation guide. If we want "one ring to bind them", it needs to have a name, and I need to be be able to use it meaningfully. This would be extremely important for IHE adoption, because we want to ensure consistency. IHE already has document content that isn't included in the CDA Consolidation guide. How would we be able to assert consistency with it?
What does optional or recommended really mean?
A guide that asserts the Consolidation template identifier is stating that it is doing things consistently with what the guide indicates. If the guide says that severity is recorded in this way, and the instance record severity differently, and the severity assessment is optional, has the guide conformed? While the instance might conform to the allowed model, it really has failed to follow the intent of the guide. The guide says to record severity this way, and the instance didn't. This is an incompatibility that would later need to be resolved if the new guide were "brought in" to the CDA Consolidation guide.
It's a brand, not just a guide!
This is my last rationale for inclusion of this, and probably the weakest from a technical perspective, but strongest from an implementation perspective. As HL7 learned from developing the CCD, everybody wanted to be able to call everything a CCD, but not everything was. This gives HL7 something that allows everybody to use CDA Consolidation, even when it doesn't have the exact document they need, and still claim conformance to the guide.

Thursday, August 4, 2011
C32 questions now being routed through Australia
Grahame Grieve has an "Ask me a question button" on his blog. He routed this one my way:
With regard to the data elements that a section may have, HITSP and IHE both have required entries which are described within their respective sections. Any entry required by IHE is also required by HITSP, and HITSP has additional vocabulary requirements, so you can locate the necessary entries within the HITSP C83 document. Other entries are permitted by both IHE and HITSP. They simply aren't specified. This stems from the idea that these are open templates that others could further constrain by adding new requirements for a more specific use case.
With regard to using the data elements from the HITSP C83, that would be good enough to understand all HITSP specified data elements that you might receive, but it is NOT an exhaustive list due to the openness described above. That being said, if it can be done using a HITSP template, C83 does say you have to use the HITSP specification for it.
Now, to add that "Ask me a question button" to this blog.
1.What is difference between various documents published by IHE andThe HITSP specifications are based up, and refer to the content of the IHE specifications. For example, HITSP C28 makes use of the IHE EDES profile and requires a conforming instance to also comply with the IHE requirements.
HITSP. they looks similar
For example HITSP C28 vs IHE(Emergency Department Encounter Summary)
2. IHE profiles provide the sections of a clinical documents, but how
do i know what are the data elements a section may have and the XML
representation of the data elements.
EG.for Review of Systems what are the data elements we may have inside
the ENTRY tag.
3. if i create a database using all data elements from HITSP C-83,
would that be good enough to store all data elements i may receive in
all kind of CDA(C28,C48, XDS-MS, healtstory etc) documents.
With regard to the data elements that a section may have, HITSP and IHE both have required entries which are described within their respective sections. Any entry required by IHE is also required by HITSP, and HITSP has additional vocabulary requirements, so you can locate the necessary entries within the HITSP C83 document. Other entries are permitted by both IHE and HITSP. They simply aren't specified. This stems from the idea that these are open templates that others could further constrain by adding new requirements for a more specific use case.
With regard to using the data elements from the HITSP C83, that would be good enough to understand all HITSP specified data elements that you might receive, but it is NOT an exhaustive list due to the openness described above. That being said, if it can be done using a HITSP template, C83 does say you have to use the HITSP specification for it.
Now, to add that "Ask me a question button" to this blog.

Thursday, May 5, 2011
Comments on the CDA Consolidation Guide
This is the last thing you are going to hear from me on this topic for a little while ... at least until the HL7 Working Group Meeting later this month.
I just uploaded my ballot comments (an Excel spreadsheet) on the HL7 CDA Consolidation Guide. I copied my comments verbatim from what IHE prepared and agreed to this afternoon. There was barely enough time to prepare those, and all we looked at were problems, medications and allergies. Some of the comments also came out of the CDA Documentation Work group's review of the project against requirements the work group agreed upon.
Overall, I'm very disappointed with what has been produced to date. I'm also uncertain as to the future of this project. We sorely missed our goals in this round of balloting. There's a tendency in the Structured Documents workgroup to push to meet arbitrary and/or unreasonable deadlines (in my personal opinion). This is especially true when there are external forces like our national agenda pushing so dreadfully hard on this project. It's hard to get anyone to slow down. The idea that this guide could become the basis for Meaningful Use Stage 2 still has a lot of people excited.
The project has got a LOT of potential, and I still support it. We need to take a step back from the current deadlines. If they remain, I don't believe the project will succeed.
What we need is a tool that will solve the problem. To get there, we need to understand the requirements that tool must meet. That includes the template meta-model the tool must support, the requirements on the documentation that the tool must produce, and requirements on production of the end result.
We also need the data of the pre-existing work, entered into the tool, and vetted against existing conformance critiera. Getting at the HL7, IHE and HITSP conformance data is not an insurmountable task. Much of it is already in machine readable form (Schematron) and structured text (even if it is Microsoft word tables or PDF files). Extracting and Vetting the data is tedious but doable. I've previously extracted data from IHE and HITSP specifications before -- it truly can be mind-numbing. It takes about a week or so (effort, not elapsed time -- that's much longer in my world).
This is what it takes to get the data:
After we have the existing template data, we can import it into MDHT. Then we need to modify the constraints to produce the new templates, and compare the differences. That comparison can be automated if the template meta-model is appropriately designed.
Trying to re-architect something that took six years to develop across three organizations which includes hundreds of templates and thousands of rules should NOT be done manually. I was involved in most of these efforts, and I did quite a bit of that work manually. It wouldn't hold together today if it hadn't been for the efforts of one person who QA'd that work across the same set of organizations. It won't scale. People cannot keep up with what we need.
But what did we do in the CDA consolidation process? We relied on people to identify inconsistencies when software would have done a better job. We relied on people to create examples when software could have done so more accurately. We still rely on people to produce the final schematron. We relied on people to produce a change log. We relied on people when what we wanted to start with was automation.
Let's get smart, and go back and build the automation that we want. MDHT is a great start. All you need do is compare this (HL7 Genetic Testing Report Guide ZIP file using MDHT) to this (CDA Consolidation ballot).
And what should we do in the interim while we develop MDHT? Well, six years of effort may not have produced the greatest set of implementation guides, but C83 and C80 work for us already today. More than 250 EHRs support much of it already. A couple of small changes in Meaningful Use stage 2 would accomplish many of the documentation goals that the Transfers of Care project has. C83 already includes templates that support H&P, Progress Notes, Consult Notes, Emergency Deparment Encounters, Referrals and Discharge Summaries. These come from the very same source projects that the CDA Consolidation project is working with. If you cannot wait for harmonized output from MDHT, then the next best thing is to work with the harmonized results that we humans produced over the last six years.
I just uploaded my ballot comments (an Excel spreadsheet) on the HL7 CDA Consolidation Guide. I copied my comments verbatim from what IHE prepared and agreed to this afternoon. There was barely enough time to prepare those, and all we looked at were problems, medications and allergies. Some of the comments also came out of the CDA Documentation Work group's review of the project against requirements the work group agreed upon.
Overall, I'm very disappointed with what has been produced to date. I'm also uncertain as to the future of this project. We sorely missed our goals in this round of balloting. There's a tendency in the Structured Documents workgroup to push to meet arbitrary and/or unreasonable deadlines (in my personal opinion). This is especially true when there are external forces like our national agenda pushing so dreadfully hard on this project. It's hard to get anyone to slow down. The idea that this guide could become the basis for Meaningful Use Stage 2 still has a lot of people excited.
The project has got a LOT of potential, and I still support it. We need to take a step back from the current deadlines. If they remain, I don't believe the project will succeed.
What we need is a tool that will solve the problem. To get there, we need to understand the requirements that tool must meet. That includes the template meta-model the tool must support, the requirements on the documentation that the tool must produce, and requirements on production of the end result.
We also need the data of the pre-existing work, entered into the tool, and vetted against existing conformance critiera. Getting at the HL7, IHE and HITSP conformance data is not an insurmountable task. Much of it is already in machine readable form (Schematron) and structured text (even if it is Microsoft word tables or PDF files). Extracting and Vetting the data is tedious but doable. I've previously extracted data from IHE and HITSP specifications before -- it truly can be mind-numbing. It takes about a week or so (effort, not elapsed time -- that's much longer in my world).
This is what it takes to get the data:
- For documents: Extract table to spreadsheet. Normalize to common format. Generate XML from spreadsheet rows.
- For sections: Same general idea.
- Conformance constraints: Extract these from source documents based on a conformance style (I built a list of constraints in HITSP specs by ensuring all constraints used the same style, then generated a TOC using word from that style (w/o page numbers). If no common style is used, create and apply one manually (mind-numbing but actually pretty quick work).
After we have the existing template data, we can import it into MDHT. Then we need to modify the constraints to produce the new templates, and compare the differences. That comparison can be automated if the template meta-model is appropriately designed.
Trying to re-architect something that took six years to develop across three organizations which includes hundreds of templates and thousands of rules should NOT be done manually. I was involved in most of these efforts, and I did quite a bit of that work manually. It wouldn't hold together today if it hadn't been for the efforts of one person who QA'd that work across the same set of organizations. It won't scale. People cannot keep up with what we need.
But what did we do in the CDA consolidation process? We relied on people to identify inconsistencies when software would have done a better job. We relied on people to create examples when software could have done so more accurately. We still rely on people to produce the final schematron. We relied on people to produce a change log. We relied on people when what we wanted to start with was automation.
Let's get smart, and go back and build the automation that we want. MDHT is a great start. All you need do is compare this (HL7 Genetic Testing Report Guide ZIP file using MDHT) to this (CDA Consolidation ballot).
And what should we do in the interim while we develop MDHT? Well, six years of effort may not have produced the greatest set of implementation guides, but C83 and C80 work for us already today. More than 250 EHRs support much of it already. A couple of small changes in Meaningful Use stage 2 would accomplish many of the documentation goals that the Transfers of Care project has. C83 already includes templates that support H&P, Progress Notes, Consult Notes, Emergency Deparment Encounters, Referrals and Discharge Summaries. These come from the very same source projects that the CDA Consolidation project is working with. If you cannot wait for harmonized output from MDHT, then the next best thing is to work with the harmonized results that we humans produced over the last six years.

Tuesday, January 11, 2011
Standards Conformance Terminology across IHE, HITSP and HL7
One of the discussions the HL7 Structured Documents Workgroup held in Sydney was with the HL7 Conformance committee. The topic of discussion was use of conformance terminology, and was applicable to the HL7/IHE/ONC consolidation project. The results of the discussion were recorded on the HL7 Wiki. The first part of what was written is pretty much dead on. The R2 = Should in IHE requires some clarification.
If you haven't already, you MUST become familiar with RFC 2119. This is the standard for standards makers on the use of the terms MUST, MUST NOT, REQUIRED, SHALL, SHALL NOT, SHOULD, SHOULD NOT, RECOMMENDED, MAY, and OPTIONAL.
The HL7 Publishing Facilitators Guide uses a subset of these terms: SHALL, SHALL NOT, SHOULD, SHOULD NOT, and MAY, and adds NEED NOT as the alternative for MAY stated in the "optional negative sense". The subset is based on discussions of terms that needed to be used according to HL7 interpretation of ANSI rules.
IHE and HITSP use the terms SHALL, SHALL NOT, SHOULD, SHOULD NOT, and MAY most often and in the way that they are defined in RFC 2119, but make no direct reference to these terms.
HL7 uses the terms mandatory and required in HL7 Version 3 modeling, and in conformance statements. Mandatory means that a data element in a message or document SHALL be present and SHALL not be empty (or contain an exceptional value or nullFlavor [all of which are essentially the same statement]). Required means the a data element in a message or document SHALL be present, but MAY be empty (or contain an exceptional value or nullFlavor). In tabular form, these are often shortened to M and R. Data items in an HL7 model are always at a level no more granular than the HL7 data type or class contained in the model. So, HL7 conformance statements using Mandatory/Required don't talk directly about the XML produced, but only do so through implication and application of the XML ITS. Structured Documents CDA implementation guides have transitioned to talking about the XML being produced, and have conformance statements on the XML element content and sometimes the XML attributes. I find this preferable from an implementer perspective because it addresses what needs to appear "on the wire", and that is where interoperability is most dramatically apparent. The shift from HL7 class and class attribute dotted notation (e.g., ClinicalDocument.code) to XPath expressions (/ClinicalDocument/code) was subtle but powerful shift that made the guides readily understood by XML aware implementers.
IHE also uses the terms Required (R), Required if Known (R2), Conditional (C), and Optional (O) in its specifications. Required if Known is a special sort of conditional that means "if you have the data, you SHALL send it." The use of term R2 comes from the DICOM standard which has a "Type 2 Required Element". From Section 7.4.3 of Part 5 of DICOM standard:
IODs and SOP Classes define Type 2 Data Elements that shall be included and are mandatory Data Elements. However, it is permissible that if a Value for a Type 2 element is unknown it can be encoded with zero Value Length and no Value.
The Type 2 Required element in DICOM is most like Required in HL7 Version 3 modeling. BTW: DICOM uses Mandatory in much the same way that HL7 V3 does.
When applied to templates created by IHE PCC, R is identical to the use of SHALL requirement [an item using template X SHALL be present], and R2 most closely interpreted as SHOULD [an item using template X SHOULD be present], but the approximation is not exact. Realistically, it means that if you capture the data, you must send it, but there is no requirement that you must capture the data (see HL7 V2 discussion of RE below). If the section is not present, IHE does not require you to send an empty length section, instead you simply omit the data. From a testing/conformance perspective, what I'd like to see for all R2 constraints on document sections is that Document Creators must either demonstrate the ability to create the content, or state clearly that their product does not capture the data and therefore cannot send the information. Note that IHE PCC has no requirements on document consumers with respect to what they do with the data, so there is no specific requirement that a document section be dealt with by the receiver in the IHE profiles. As Kevin Coonan pointed out to me in a side channel discussion on todays Consolidation call, the IHE PCC R2 is a dynamic, rather than static conformance criteria.
HL7 Version 2 has a set of conformance abbreviations it uses on fields described in a conformance profile. In addition to Required (R), Conditional (C) and Optional (O), it has Required but may be Empty (RE), and Conditional but may be Empty (CE). RE in HL7 V2 and R2 in an IHE profile have nearly the same meaning, but HL7's definition for RE is stronger. It indicates that an application MUST have the ability to send something in a field using RE in a conformance profile, while IHE PCC's use of R2 is a little weaker.
In profiling HL7, IHE sometimes uses R+ as well to indicate things that IHE has made Required which HL7 said were optional, just to make our lives a little easier.
I hope that clears things up about the current state of affairs.
Frankly, I prefer SHALL, SHOULD and MAY, because all of these shortcuts make it a lot harder to understand. Later profiles in IHE PCC created after the great R2 debate of a couple of years ago (initiated by HITSP and spawned through IHE and HL7). It is apparent after discussions with HL7 conformance that the discussion is not yet over, and that IHE will need to review its use of R2 in existing final text PCC profiles (XDS-MS, EDR, and XPHR) to ensure that we clearly capture the intent of the committee as it stood at the time the profile was created, and appropriately clarify its terminology. The Consolidation project will capture the intent as we move forward on those final text IHE profiles which become part of the work.
I'd also enjoy seeing a reference to RFC 2119 be used in IHE, and HL7 (although that is a losing battle, as the current terms are hard fought based on HL7 perceptions of ANSI rules).
In almost all of this discussion of conformance constraints, I have been talking about sender / creator responsibilities, and not about the receiver responsibilities to do something with the data that is sent to it. This is mostly because many of us can imagine some very innovative ways for a receiver to do something with just one tiny bit of the message that we don't want to prevent by requiring the receiver to do anything more than accept a valid message.
Keith
If you haven't already, you MUST become familiar with RFC 2119. This is the standard for standards makers on the use of the terms MUST, MUST NOT, REQUIRED, SHALL, SHALL NOT, SHOULD, SHOULD NOT, RECOMMENDED, MAY, and OPTIONAL.
The HL7 Publishing Facilitators Guide uses a subset of these terms: SHALL, SHALL NOT, SHOULD, SHOULD NOT, and MAY, and adds NEED NOT as the alternative for MAY stated in the "optional negative sense". The subset is based on discussions of terms that needed to be used according to HL7 interpretation of ANSI rules.
IHE and HITSP use the terms SHALL, SHALL NOT, SHOULD, SHOULD NOT, and MAY most often and in the way that they are defined in RFC 2119, but make no direct reference to these terms.
HL7 uses the terms mandatory and required in HL7 Version 3 modeling, and in conformance statements. Mandatory means that a data element in a message or document SHALL be present and SHALL not be empty (or contain an exceptional value or nullFlavor [all of which are essentially the same statement]). Required means the a data element in a message or document SHALL be present, but MAY be empty (or contain an exceptional value or nullFlavor). In tabular form, these are often shortened to M and R. Data items in an HL7 model are always at a level no more granular than the HL7 data type or class contained in the model. So, HL7 conformance statements using Mandatory/Required don't talk directly about the XML produced, but only do so through implication and application of the XML ITS. Structured Documents CDA implementation guides have transitioned to talking about the XML being produced, and have conformance statements on the XML element content and sometimes the XML attributes. I find this preferable from an implementer perspective because it addresses what needs to appear "on the wire", and that is where interoperability is most dramatically apparent. The shift from HL7 class and class attribute dotted notation (e.g., ClinicalDocument.code) to XPath expressions (/ClinicalDocument/code) was subtle but powerful shift that made the guides readily understood by XML aware implementers.
IHE also uses the terms Required (R), Required if Known (R2), Conditional (C), and Optional (O) in its specifications. Required if Known is a special sort of conditional that means "if you have the data, you SHALL send it." The use of term R2 comes from the DICOM standard which has a "Type 2 Required Element". From Section 7.4.3 of Part 5 of DICOM standard:
IODs and SOP Classes define Type 2 Data Elements that shall be included and are mandatory Data Elements. However, it is permissible that if a Value for a Type 2 element is unknown it can be encoded with zero Value Length and no Value.
The Type 2 Required element in DICOM is most like Required in HL7 Version 3 modeling. BTW: DICOM uses Mandatory in much the same way that HL7 V3 does.
When applied to templates created by IHE PCC, R is identical to the use of SHALL requirement [an item using template X SHALL be present], and R2 most closely interpreted as SHOULD [an item using template X SHOULD be present], but the approximation is not exact. Realistically, it means that if you capture the data, you must send it, but there is no requirement that you must capture the data (see HL7 V2 discussion of RE below). If the section is not present, IHE does not require you to send an empty length section, instead you simply omit the data. From a testing/conformance perspective, what I'd like to see for all R2 constraints on document sections is that Document Creators must either demonstrate the ability to create the content, or state clearly that their product does not capture the data and therefore cannot send the information. Note that IHE PCC has no requirements on document consumers with respect to what they do with the data, so there is no specific requirement that a document section be dealt with by the receiver in the IHE profiles. As Kevin Coonan pointed out to me in a side channel discussion on todays Consolidation call, the IHE PCC R2 is a dynamic, rather than static conformance criteria.
HL7 Version 2 has a set of conformance abbreviations it uses on fields described in a conformance profile. In addition to Required (R), Conditional (C) and Optional (O), it has Required but may be Empty (RE), and Conditional but may be Empty (CE). RE in HL7 V2 and R2 in an IHE profile have nearly the same meaning, but HL7's definition for RE is stronger. It indicates that an application MUST have the ability to send something in a field using RE in a conformance profile, while IHE PCC's use of R2 is a little weaker.
In profiling HL7, IHE sometimes uses R+ as well to indicate things that IHE has made Required which HL7 said were optional, just to make our lives a little easier.
I hope that clears things up about the current state of affairs.
Frankly, I prefer SHALL, SHOULD and MAY, because all of these shortcuts make it a lot harder to understand. Later profiles in IHE PCC created after the great R2 debate of a couple of years ago (initiated by HITSP and spawned through IHE and HL7). It is apparent after discussions with HL7 conformance that the discussion is not yet over, and that IHE will need to review its use of R2 in existing final text PCC profiles (XDS-MS, EDR, and XPHR) to ensure that we clearly capture the intent of the committee as it stood at the time the profile was created, and appropriately clarify its terminology. The Consolidation project will capture the intent as we move forward on those final text IHE profiles which become part of the work.
I'd also enjoy seeing a reference to RFC 2119 be used in IHE, and HL7 (although that is a losing battle, as the current terms are hard fought based on HL7 perceptions of ANSI rules).
In almost all of this discussion of conformance constraints, I have been talking about sender / creator responsibilities, and not about the receiver responsibilities to do something with the data that is sent to it. This is mostly because many of us can imagine some very innovative ways for a receiver to do something with just one tiny bit of the message that we don't want to prevent by requiring the receiver to do anything more than accept a valid message.
Keith

Friday, August 13, 2010
Can you imagine this nurse on a Harley?
OK, so I should have given this award on May 6th, but I didn't. As a reminder, the Ad Hoc Harley award is something that I do that is completely arbitrary. There is no nomination committee, but nominations are always welcome. The purpose of the award is to recognize the contributions of people to the field of healthcare IT, and it already has a history of excellence.
I've known the next recipient for more than six years. She's always been supportive of my efforts in HCIT, but they are just a drop in the bucket compared to what she has managed to accomplish. Under her leadership, one organization went from being a co-sponsored project between several medical professional societies to being one of the World's most influential non-profit corporations dedicated to the advancement of interoperability.
She's overseen the implementation of federal contracts which harmonized specifications across more than a dozen different SDOs, and a half-gross of standards.
In one of her newest roles, she will help advance HIT interoperability deployment efforts in the United States as an officer of IHE USA, Inc.
Her latest blog post talks about how unlikely it will be for the Healthcare industry to achieve ARRA objectives without nurses (link below after the award).
A pair of nurse colleagues of mine stood in the IHE Interoperability showcase at HIMSS more than 3 years ago. I introduced them to this nurse, who was behind everything that Showcase has become. She spent a good bit of time talking to the two of them. I explained who she was afterwards, and what she had done, and one colleague turned to the other and said: "All this because of just one Nurse..."
Joyce will undoubtedly tell you that she didn't do it alone and that she had the help of many other nurses and other professionals in her journey. She may be right, but, she still deserves recognition.
Joyce, congratulations, and think of yourself as a representative for all nurses, which is how you have acted for as long as I have known you.
Here's a link to her recent blog post, which made me realize how overdue this award was.
I've known the next recipient for more than six years. She's always been supportive of my efforts in HCIT, but they are just a drop in the bucket compared to what she has managed to accomplish. Under her leadership, one organization went from being a co-sponsored project between several medical professional societies to being one of the World's most influential non-profit corporations dedicated to the advancement of interoperability.
She's overseen the implementation of federal contracts which harmonized specifications across more than a dozen different SDOs, and a half-gross of standards.
In one of her newest roles, she will help advance HIT interoperability deployment efforts in the United States as an officer of IHE USA, Inc.
Her latest blog post talks about how unlikely it will be for the Healthcare industry to achieve ARRA objectives without nurses (link below after the award).
A pair of nurse colleagues of mine stood in the IHE Interoperability showcase at HIMSS more than 3 years ago. I introduced them to this nurse, who was behind everything that Showcase has become. She spent a good bit of time talking to the two of them. I explained who she was afterwards, and what she had done, and one colleague turned to the other and said: "All this because of just one Nurse..."
This certifies that
Joyce Sensmeier, MS, RN-BC, CPHIMS, FHIMSS
of HIMSS
of HIMSS
Has hereby been recognized for outstanding contributions to the forwarding of Healthcare Standardization
Joyce will undoubtedly tell you that she didn't do it alone and that she had the help of many other nurses and other professionals in her journey. She may be right, but, she still deserves recognition.
Joyce, congratulations, and think of yourself as a representative for all nurses, which is how you have acted for as long as I have known you.
Here's a link to her recent blog post, which made me realize how overdue this award was.

Tuesday, July 27, 2010
Moving from C32 Version 2.3 to 2.5
Updated 12/15/2010 to provide an example for uncoded, and added examples for value elements.
Just for fun, I'm going to pretend that you have ignored my recommendation to use HITSP C32 Version 2.5, and are using an older version, like C32 Version 2.3. Maybe you had 2.3 already implemented, and were waiting to see what happened to meaningful use before you piled on more work. So, now you want to know what you need to do to make the switch?
Note: You could remove the template 2.16.840.1.113883.3.88.11.32.2, but need not, and this pattern follows throughout for the 88.11.32.xx templates.
Where you had...
Notes:
*HCPCS is made up of CPT-4 and several other vocabularies. This is just the OID for CPT-4, I'm still digging into the remainder.
**C32 Version 2.5 does not have a preferred vocabulary for procedures, so any code system can be used in the code element
***ICD-9-CM Procedures uses a different OID than ICD-9-CM Diagnoses, this is NOT a mistake
Warning: These aren't necessarily all of the changes that you will need to make to your application, but it does cover the largest ones.
Just for fun, I'm going to pretend that you have ignored my recommendation to use HITSP C32 Version 2.5, and are using an older version, like C32 Version 2.3. Maybe you had 2.3 already implemented, and were waiting to see what happened to meaningful use before you piled on more work. So, now you want to know what you need to do to make the switch?
Moving to V2.4
Fortunately, it's not really all that difficult. Between version 2.3 and version 2.4, the big change was the introduction of C83 (CDA Content Modules) and the harmonization of HITSP Section and Entry templates across HITSP Components. Some HITSP specifications (like C28, C38 and C48) used IHE Profiles, others (like C84) used Health Story/HL7 Implementation Guides, and others (like C32), just used straight CCD. Making the shift between Version 2.3 and 2.4 was basically a matter of replacing the ...88.11.32.xx template identifiers with the ...88.11.83.yy template identifiers (where xx == yy in almost all cases), and adding a few IHE template identifiers. Here are the major changes you need to make:In the CDA Document
Where you had:‹ClinicalDocument ...› ‹templateId root='2.16.840.1.113883.3.88.11.32.1 '/› ‹templateId root='2.16.840.1.113883.10.20.1 '/›You would add the following:
‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.1.6'/› ‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.1.2'/› ‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.1.1'/› ‹templateId root='2.16.840.1.113883.10.20.3'/›
In the CDA Header
Where you had...‹languageCommunication› ‹templateId root='2.16.840.1.113883.3.88.11.32.2'/›Add...
‹templateId root='2.16.840.1.113883.3.88.11.83.2'/› ‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.2.1'/›
Note: You could remove the template 2.16.840.1.113883.3.88.11.32.2, but need not, and this pattern follows throughout for the 88.11.32.xx templates.
Where you had...
‹participant...› ‹templateId root='2.16.840.1.113883.3.88.11.32.3'/›Add...
‹templateId root='2.16.840.1.113883.3.88.11.83.3'/› ‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.2.4'/›Where you had...
‹performer...› ‹templateId root='2.16.840.1.113883.3.88.11.32.4'/›Add...
‹templateId root='2.16.840.1.113883.3.88.11.83.4'/› ‹templateId root='1.3.6.1.4.1.19376.1.5.3.1.2.3'/›
In Sections
For each of the sections below, add the specified templates to either the section or the entry| Section Name | In this CCD Section | Add these Section Templates | In this C32/CCD Entry | Add these Entry Templates |
| Insurance Providers | 2.16.840.1.113883.10.20.1.9 | 2.16.840.1.113883.3.88.11.83.101.1 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.7 | 2.16.840.1.113883.3.88.11.32.5 2.16.840.1.113883.10.20.1.20 | 2.16.840.1.113883.3.88.11.83.5.1 1.3.6.1.4.1.19376.1.5.3.1.4.17 |
| Allergies | 2.16.840.1.113883.10.20.1.2 | 2.16.840.1.113883.3.88.11.83.102 1.3.6.1.4.1.19376.1.5.3.1.3.13 | 2.16.840.1.113883.3.88.11.32.6 2.16.840.1.113883.10.20.1.27 | 2.16.840.1.113883.3.88.11.83.6 1.3.6.1.4.1.19376.1.5.3.1.4.5.3 |
| Problems | 2.16.840.1.113883.10.20.1.11 | 2.16.840.1.113883.3.88.11.83.103 1.3.6.1.4.1.19376.1.5.3.1.3.6 | 2.16.840.1.113883.3.88.11.32.7 2.16.840.1.113883.10.20.1.27 | 2.16.840.1.113883.3.88.11.83.7 1.3.6.1.4.1.19376.1.5.3.1.4.5.2 |
| Medications | 2.16.840.1.113883.10.20.1.8 | 2.16.840.1.113883.3.88.11.83.112 1.3.6.1.4.1.19376.1.5.3.1.3.19 | 2.16.840.1.113883.3.88.11.32.8 2.16.840.1.113883.10.20.1.24 | 2.16.840.1.113883.3.88.11.83.8 1.3.6.1.4.1.19376.1.5.3.1.4.7 |
| Product | 2.16.840.1.113883.10.20.1.53 | 2.16.840.1.113883.3.88.11.83.8.2 1.3.6.1.4.1.19376.1.5.3.1.4.7.2 | ||
| Advance Directives | 2.16.840.1.113883.10.20.1.1 | 2.16.840.1.113883.3.88.11.83.116 1.3.6.1.4.1.19376.1.5.3.1.3.35 | 2.16.840.1.113883.3.88.11.32.13 2.16.840.1.113883.10.20.1.17 | 2.16.840.1.113883.3.88.11.83.12 1.3.6.1.4.1.19376.1.5.3.1.4.13.7 |
| Immunization | 2.16.840.1.113883.10.20.1.6 | 2.16.840.1.113883.3.88.11.83.117 1.3.6.1.4.1.19376.1.5.3.1.3.23 | 2.16.840.1.113883.3.88.11.32.14 2.16.840.1.113883.10.20.1.24 | 2.16.840.1.113883.3.88.11.83.13 1.3.6.1.4.1.19376.1.5.3.1.4.12 |
| Vital Signs | 2.16.840.1.113883.10.20.1.16 | 2.16.840.1.113883.3.88.11.83.119 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.2 | 2.16.840.1.113883.3.88.11.32.15 2.16.840.1.113883.10.20.1.31 | 2.16.840.1.113883.3.88.11.83.14 1.3.6.1.4.1.19376.1.5.3.1.4.13.1 |
| Result | 2.16.840.1.113883.10.20.1.14 | 2.16.840.1.113883.3.88.11.83.122 1.3.6.1.4.1.19376.1.5.3.1.3.28 | 2.16.840.1.113883.3.88.11.32.16 2.16.840.1.113883.10.20.1.31 | 2.16.840.1.113883.3.88.11.83.15.1 1.3.6.1.4.1.19376.1.5.3.1.4.13 |
| Procedures | 2.16.840.1.113883.10.20.1.12 | 2.16.840.1.113883.3.88.11.83.108 1.3.6.1.4.1.19376.1.5.3.1.3.12 | 2.16.840.1.113883.10.20.1.29 | 2.16.840.1.113883.3.88.11.83.17 1.3.6.1.4.1.19376.1.5.3.1.4.19 |
| Encounters | 2.16.840.1.113883.10.20.1.3 | 2.16.840.1.113883.3.88.11.83.127 1.3.6.1.4.1.19376.1.5.3.1.1.5.3.3 | 2.16.840.1.113883.3.88.11.32.17 2.16.840.1.113883.10.20.1.21 | 2.16.840.1.113883.3.88.11.83.16 1.3.6.1.4.1.19376.1.5.3.1.4.14 |
| Comment | 2.16.840.1.113883.3.88.11.32.12 2.16.840.1.113883.10.20.1.40 | 2.16.840.1.113883.3.88.11.83.11 1.3.6.1.4.1.19376.1.5.3.1.4.2 |
Moving to V2.5
The major change affecting C32 going from version 2.4 to 2.5 were modifications supporting the meaningful use code sets. If you had already supported the HITSP code sets use in C32 Version 2.3, this didn't really effect you as a producer. As a consumer of C32 Version 2.5, there was a significant change related to coded content. For many of the C32 entries, there was one and only one allowed code system, and if you included the ‹code› element, you used the required code system. In Version 2.5 the requirements were clarified. There are two ways to use ‹code› or the CD data type in ‹value›- Coded data using required vocabularies.
In this case, the code and codeSystem attributes are required on ‹code› and contain the codes in the required code set. So, for problems, if you used SNOMED-CT, you'd do something like the following:
‹code code='57054005' codeSystem='2.16.840.1.113883.6.96'/› ‹value xsi:type='CD' code='57054005' codeSystem='2.16.840.1.113883.6.96'/›
- Coded using other than required vocabularies
In this case, the nullFlavor attribute is required. If coded using other than the required vocabulary, the alternate code goes in ‹translation›, and the code and codeSystem attributes of the ‹translation› identify the code using an alternative coding scheme. And if you used ICD-9-CM for problems, you'd do something like the following:
‹code nullFlavor='UNK'› ‹translation code='410.9' codeSystem='2.16.840.1.113883.6.103'/› ‹/code› ‹value xsi:type='CD' nullFlavor='UNK'› ‹translation code='410.9' codeSystem='2.16.840.1.113883.6.103'/› ‹/value›
- Not coded at all again requires nullFlavor:
‹code nullFlavor='UNK'/› ‹value xsi:type='CD' nullFlavor='UNK'/›
| Coded Item | Vocabulary | OID | Code/Translation |
| Problems | SNOMED CT | 2.16.840.1.113883.6.96 | C |
| ICD-9-CM | 2.16.840.1.113883.6.103 | T | |
| Medications | RxNORM | 2.16.840.1.113883.6.88 | C |
| NDC | 2.16.840.1.113883.6.69 | T | |
| MDDB (Medispan) | 2.16.840.1.113883.6.162 | T | |
| MMSL (Multum) | 2.16.840.1.113883.6.175 | T | |
| NDDF (First DataBank) | 2.16.840.1.113883.6.208 | T | |
| MMX (MicroMedex) | 2.16.840.1.113883.6.176 | T | |
| MSH (MeSH) | 2.16.840.1.113883.6.177 | T | |
| NDFRT (VHA National Drug File) | 2.16.840.1.113883.6.209 | T | |
| SNOMED CT | 2.16.840.1.113883.6.96 | T | |
| Lab Tests | LOINC | 2.16.840.1.113883.6.1 | C |
| Procedures | CPT-4* | 2.16.840.1.113883.6.12 | C** |
| ICD-9-CM | 2.16.840.1.113883.6.104*** | C** |
Notes:
*HCPCS is made up of CPT-4 and several other vocabularies. This is just the OID for CPT-4, I'm still digging into the remainder.
**C32 Version 2.5 does not have a preferred vocabulary for procedures, so any code system can be used in the code element
***ICD-9-CM Procedures uses a different OID than ICD-9-CM Diagnoses, this is NOT a mistake
Warning: These aren't necessarily all of the changes that you will need to make to your application, but it does cover the largest ones.

Tuesday, July 13, 2010
Meaningful Use Standards Summary
Click the link for information on Stage 2.
Rarely do I add something to a post after the fact that isn't a correction, but then few posts ever get this much attention so many days later. If you are interested in this post, there are more some more goodies you may want to look at. I especially recommend the first.
This morning, HHS published the final rule for Health Information Technology: Initial Set of Standards, Implementation Specifications, and Certification Criteria for Electronic Health Record Technology for public display (see http://www.ofr.gov/OFRUpload/OFRData/2010-17210_PI.pdf).
- While both CCD and CCR are retained as the standards for patient summaries, HHS requires the use of the HITSP C32 Version 2.5 (the version updated for the IFR) when CCD is used. This made my day, as the work I have been doing for the last 5 years is now incorporated into the final regulation text.
- Transport standards (SOAP and REST) have been removed from the Standards Final Rule.
- The requirement to use Electronic claims and eligibility transactions has been removed from the final rule, but is expected for 2013.
- For immunizations, the final rule now requires the CDC Implementation Guide for HL7 Version 2.3.1, or the new 1.0 guide using HL7 Version 2.5.1.
- For public health reporting the HL7 2.5.1 Public Health Information Network implementation guide is required to be used when HL7 2.5.1 is used (2.3.1 is also permitted and does not have a guide [thanks to Hans Buitendijk of Siemens for this catch])
- Standards for cross-enterprise user authentication have been removed.
- Rather than specifying AES for encryption, the final rule now references approved security functions found in Annex-A of FIPS 140-2. This allows most existing VPN connections and operating system encryption capabilities to continue to be used to meet the certification requirements.
- Accounting for disclosures is now an “optional” critieria.
- CPOE is no longer required for referrals, only meds, labs, and imaging/diagnostic tests.
- Both NCPDP SCRIPT 8.1 and 10.6 are allowed (10.6 was recently allowed under Medicare Part D rules).
- OMB guidelines must be followed when reporting race and ethnicity. These guidelines do not specify code values, only the specific concepts that the codes must be able to roll up to. The CDC Race and Ethnicity Code set is one such code set that supports this.
- Discharge summary requirement retained, but their inclusion in CCD/CCR not required. ONC recognized that they are not supported by the selected standards.
- HHS states that SNOMED-CT is allowed to report procedures. However, this is apparently an error (see the next post), since ICD-9-CM is the alternative for procedures found in the regulation in that section.
- The HL7 Version 2.5.1 Electronic Laboratory Reporting implementation guide (the link only works if you are an HL7 member and logged in) is required for submission of laboratory results to public health. This guide is available for purchase from HL7 for $50 according to Rita Altamore, and HL7 is updating their site to make it more accessible.
- A certified Hospital EHR must be able to record the availability of an Advance Directive.
HHS estimates the one-time costs for EHR developers to certify products will range from $750,000 to $4,800,000 depending upon whether the EHR has previously been certified or not. But also, they note that they believe the rule will not create a significant hardship on small business entities that produce EHR systems.
Thanks to Hans J. Buitendijk and David Tao of Siemens, Rob Savage (Northrup Grummund/CDC), Austin Kreisler (SAIC/CDC), Rita Altamore (Washington Deptartment of Health), and Nikolay Lipskiy (CDC) for the links to the various guides and other updates.
ONC EHR Criteria - Stage 1 Final July 2010
Don Sepulvada, Sr. Marketing Manager of GE Healthcare for our Centricity® EMR product line pulled together the following table from the standards rule. This table now includes all certification criteria and requirements for Ambulatory AND Hospital EHR products. (Nice work Don!)| Rule | Meaningful Use Stage 1 Objective | Meaningful Use Stage 1 Measure | Interim Final Certification Criterion | Final Certification Criterion |
| §170.302(a) - Drug-drug, drug-allergy, drug-formulary checks | Implement drug-drug and drug-allergy interaction checks | The EP/eligible hospital/CAH has enabled this functionality for the entire EHR reporting period | Interim Final Rule Text: (1)Alerts. Automatically and electronically generate and indicate in real-time, alerts at the point of care for drug-drug and drug-allergy contraindications based on medication list, medication allergy list, age, and computerized provider order entry (CPOE). (3)Customization. Provide certain users with administrator rights to deactivate, modify, and add rules for drug-drug and drug-allergy checking. (4)Alert statistics. Automatically and electronically track, record, and generate reports on the number of alerts responded | Final Rule Text: §170.302(a) (1) Notifications. Automatically and electronically generate and indicate in real-time, notifications at the point of care for drug-drug and drug-allergy contraindications based on medication list, medication allergy list, and computerized provider order entry (CPOE). (2) Adjustments. Provide certain users with the ability to adjust notifications provided for drug-drug and drug-allergy interaction checks. |
| §170.302(a) - Drug-drug, drug-allergy, drug-formulary checks | Implement drug-formulary checks | The EP/eligible hospital/CAH has enabled this functionality and has access to at least one internal or external drug formulary for the entire EHR reporting period | Interim Final Rule Text: (2)Formulary checks. Enable a user to electronically check if drugs are in a formulary or preferred drug list in accordance with the standard specified in §170.205(b). | Final Rule Text: §170.302(b) Drug-formulary checks. Enable a user to electronically check if drugs are in a formulary or preferred drug list. |
| §170.302(b) - Maintain up-to-date problem list | Maintain an up-to-date problem list of current and active diagnoses | More than 80% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) have at least one entry or an indication that no problems are known for the patient recorded as structured data | Interim Final Rule Text: Maintain up-to-date problem list. Enable a user to electronically record, modify, and retrieve a patient’s problem list for longitudinal care in accordance with: (1) The standard specified in §170.205(a)(2)(i)(A); or (2) At a minimum, the version of the | Final Rule Text: §170.302(c) Final rule text remains the same as Interim Final Rule text, except for references to adopted standards, which have been changed. |
| §170.302(c) - Maintain active medication list | Maintain active medication list | More than 80% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) have at least one entry (or an indication that the patient is not currently prescribed any medication) recorded as structured data | Interim Final Rule Text: Maintain active medication list. Enable a user to electronically record, modify, and retrieve a patient’s active medication list as well as medication history for longitudinal care in accordance with the standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.302(d) Maintain active medication list. Enable a user to electronically record, modify, and retrieve a patient’s active medication list as well as medication history for longitudinal care. |
| §170.302(d) - Maintain active medication allergy list | Maintain active medication allergy list | More than 80% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21or 23) have at least one entry (or an indication that the patient has no known medication allergies) recorded as structured data | Interim Final Rule Text: Maintain active medication allergy list. Enable a user to electronically record, modify, and retrieve a patient’s active medication allergy list as well as medication allergy history for longitudinal care. | Final Rule Text: Unchanged Now §170.302(e) |
| §170.302(e) - Record and chart vital signs | Record and chart changes in vital signs: • Height • Weight • Blood pressure • Calculate and display BMI • Plot and display growth charts for children 2-20 years, including BMI | For more than 50% of all unique patients age 2 and over seen by the EP or admitted to eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23), height, weight and blood pressure are recorded as structured data | Interim Final Rule Text: (1)Vital signs. Enable a user to electronically record, modify, and retrieve a patient’s vital signs including, at a minimum, the height, weight, blood pressure, temperature, and pulse. (2)Calculate body mass index. Automatically calculate and display body mass index (BMI) based on a patient’s height and weight. (3) Plot and display growth charts. Plot and electronically display, upon request, growth charts for patients 2-20 years old. | Final Rule Text: §170.302(f) (1)Vital signs. Enable a user to electronically record, modify, and retrieve a patient’s vital signs including, at a minimum, height, weight, and blood pressure. (2) Unchanged (3) Unchanged |
| §170.302(f) - Smoking status | Record smoking status for patients 13 years old or older | More than 50% of all unique patients 13 years old or older seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or Emergency department (POS 21 or 23) have smoking status recorded as structured data | Interim Final Rule Text: Smoking status. Enable a user to electronically record, modify, and retrieve the smoking status of a patient. Smoking status types must include: current smoker, former smoker, or never smoked. | Final Rule Text: §170.302(g) Smoking status. Enable a user to electronically record, modify, and retrieve the smoking status of a patient. Smoking status types must include: current every day smoker; current some day smoker; former smoker; never smoker; smoker, current status unknown; and unknown if ever smoked |
| §170.302(g) - Incorporate laboratory test results | Incorporate clinical lab-test results into certified EHR technology as structured data | More than 40% of all clinical lab tests results ordered by the EP or by an authorized provider of the eligible hospital or CAH for patients admitted to its inpatient or emergency department (POS 21 or 23) during the EHR reporting period whose results are eitEHR in a positive/negative or numerical format are incorporated in certified EHR technology as structured data | Interim Final Rule Text: (1) Receive results. Electronically receive clinical laboratory test results in a structured format and display such results in human eadable format. (2) Display codes in readable format. Electronically display in human readable format any clinical laboratory tests that have been received with LOINC® codes. (3) Display test report information. Electronically display all the information for a test report specified at 42 CFR 493.1291(c)(1) through (7). (4) Update. Enable a user to electronically update a patient’s record based upon received laboratory test results. | Final Rule Text: §170.302(h) (1) Unchanged (2) Display test report information. Electronically display all the information for a test report specified at 42 CFR 493.1291(c)(1) through (7). (3) Incorporate results. Electronically attribute, associate, or link a laboratory test result to a laboratory order or patient record. |
| §170.302(h) - Generate patient lists | Generate lists of patients by specific conditions to use for quality improvement, reduction of disparities, research or outreach | Generate at least one report listing patients of the EP, eligible hospital or CAH with a specific condition | Interim Final Rule Text: Generate patient lists. Enable a user to electronically select, sort, retrieve, and output a list of patients and patients’ clinical information, based on user-defined demographic data, medication list, and specific conditions. | Final Rule Text: §170.302(i) Generate patient lists. Enable a user to electronically select, sort, retrieve, and generate lists of patients according to, at a minimum, the data elements included in: (1) Problem list; (2) Medication list; (3) Demographics; and (4) Laboratory test results. |
| §170.302(i) - Report quality measures | Eligible Professionals: Report ambulatory clinical quality measures to CMS or the States | For 2011, provide aggregate numerator, denominator, and exclusions through attestation as discussed in section II(A)(3) of [the Medicare and Medicaid EHR Incentive Programs final rule] | Interim Final Rule Text: (1) Display. Calculate and electronically display quality measures as specified by CMS or states. (2) Submission. Enable a user to electronically submit calculated quality measures in accordance with the standard and implementation specifications specified in §170.205(e). | Final Rule Text: §170.304(j) (1) Calculate. (i) Electronically calculate all of the core clinical measures specified by CMS for eligible professionals. (ii) Electronically calculate, at a minimum, three clinical quality measures specified by CMS for eligible professionals, in addition to those clinical quality measures specified in paragraph (1)(i). (2) Submission. Enable a user to electronically submit calculated clinical quality measures in accordance with the standard and implementation specifications specified in §170.205(f). |
| §170.302(j) - Check insurance eligibility and §170.302(k) - Submit claims | §170.302(j) - Check insurance eligibility Removed from final rule | Removed from final rule | Interim Final Rule Text: Enable a user to electronically record and display patients’ insurance eligibility, and submit insurance eligibility queries to public or private payers and receive an eligibility response in accordance with the applicable standards and implementation specifications specified in §170.205(d)(1) or (2). | Final Rule Text: Removed |
| §170.302(j) - Check insurance eligibility and §170.302(k) - Submit claims | eligibility and §170.302(k) - Submit claims Removed from final rule | Removed from final rule | Interim Final Rule Text: Enable a user to electronically submit claims to public or private payers in accordance with the standard and implementation specifications specified in §170.205(d)(3). | Final Rule Text: Removed |
| §170.302(l) - Medication reconciliation | The EP, eligible hospital or CAH who receives a patient from another setting of care or provider of care or believes an encounter is relevant should perform medication reconciliation | The EP, eligible hospital or CAH performs medication reconciliation for more than 50% of transitions of care in which the patient is transitioned into the care of the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) | Interim Final Rule Text: Medication reconciliation. Electronically complete medication reconciliation of two or more medication lists by comparing and merging into a single medication list that can be electronically displayed in real-time. | Final Rule Text: §170.302(j) Medication reconciliation. Enable a user to electronically compare two or more medication lists. |
| §170.302(m) - Submission to immunization registries | Capability to submit electronic data to immunization registries or Immunization Information Systems and actual submission in accordance with applicable law and practice | Performed at least one test of certified EHR technology's capacity to submit electronic data to immunization registries and follow up submission if the test is successful (unless none of the immunization registries to which the EP, eligible hospital or CAH submits such information have the capacity to receive the information electronically) | Interim Final Rule Text: Submission to immunization registries. Electronically record, retrieve, and transmit immunization information to immunization registries in accordance with: (1) One of the standards specified in §170.205(h)(1) and, at a minimum, the version of the standard specified in §170.205(h)(2); or (2) The applicable state-designated standard format. | Final Rule Text: §170.302(k) Submission to immunization registries. Electronically record, modify, retrieve, and submit immunization information in accordance with: (1) The standard (and applicable implementation specifications) specified in §170.205(e)(1) or §170.205(e)(2); and (2) At a minimum, the version of the standard specified in §170.207(e). |
| §170.302(n) - Public health surveillance | Capability to submit electronic syndromic surveillance data to public health agencies and actual submission in accordance with applicable law and practice | Performed at least one test of certified EHR technology's capacity to provide electronic syndromic surveillance data to public health agencies and follow-up submission if the test is successful (unless none of the public health agencies to which an EP, eligible hospital or CAH submits such information have the capacity to receive the information electronically) | Interim Final Rule Text: Public health surveillance. Electronically record, retrieve, and transmit syndrome-based public health surveillance information to public health agencies in accordance with one of the standards specified in §170.205(g). | Final Rule Text: §170.302(l) Public health surveillance. Electronically record, modify, retrieve, and submit syndrome-based public health surveillance information in accordance with the standard (and applicable implementation specifications) specified in §170.205(d)(1) or §170.205(d)(2). |
| §170.302(o) - Access control | Protect electronic health information created or maintained by the certified EHR technology through the implementation of appropriate technical capabilities | Conduct or review a security risk analysis per 45 CFR 164.308 (a)(1) and implement security updates as necessary and correct identified security deficiencies as part of its risk management process | Interim Final Rule Text: Access control. Assign a unique name and/or number for identifying and tracking user identity and establish controls that permit only authorized users to access electronic health information. | Final Rule Text: §170.302(o) Unchanged |
| §170.302(p) - Emergency access | Interim Final Rule Text: Emergency access. Permit authorized users (who are authorized for emergency situations) to access electronic health information during an emergency. | Final Rule Text: §170.302(p) Unchanged | ||
| §170.302(q) - Automatic log-off | Interim Final Rule Text: Automatic log-off. Terminate an electronic session after a re-determined time of inactivity. | Final Rule Text: §170.302(q) Unchanged | ||
| §170.302(r) - Audit log | Interim Final Rule Text: (1) Record actions. Record actions related to electronic health information in accordance with the standard specified in §170.210(b). (2) Alerts. Provide alerts based on user-defined events. (3) Display and print. Electronically display and print all or a specified set of recorded information upon request or at a set period of time. | Final Rule Text: §170.302(r) (1) Record actions. Record actions related to electronic health information in accordance with the standard specified in §170.210(b). (2) Generate audit log. Enable a user to generate an audit log for a specific time period and to sort entries in the audit log according to any of the elements specified in the standard at 170.210(b). | ||
| §170.302(s) - Integrity | Interim Final Rule Text: (1)In transit. Verify that electronic health information has not been altered in transit in accordance with the standard specified in §170.210(c). (2) Detection. Detect the alteration and deletion of electronic health information and audit logs, in accordance with the standard specified in §170.210(c). | Final Rule Text: §170.302(s) (1) Create a message digest in accordance with the standard specified in 170.210(c). (2) Verify in accordance with the standard specified in 170.210(c) upon receipt of electronically exchanged health information that such information has not been altered. (3) Detection. Detect the alteration of audit logs. | ||
| §170.302(t) - Authentication | Interim Final Rule Text: (1)Local. Verify that a person or entity seeking access to electronic health information is the one claimed and is authorized to access such information. (2)Cross network. Verify that a person or entity seeking access to electronic health information across a network is the one claimed and is authorized to access such information in accordance with the standard specified in §170.210(d). | Final Rule Text: §170.302(t) Authentication. Verify that a person or entity seeking access to electronic health information is the one claimed and is authorized to access such information. | ||
| §170.302(u) - Encryption | Interim Final Rule Text: (1) General. Encrypt and decrypt electronic health information according to user-defined preferences in accordance with the standard specified in §170.210(a)(1). (2) Exchange. Encrypt and decrypt electronic health information when exchanged in accordance with the standard specified in §170.210(a)(2). | Final Rule Text: §170.302(u) General encryption. Encrypt and decrypt electronic health information in accordance with the standard specified in §170.210(a)(1), unless the Secretary determines that the use of such algorithm would pose a significant security risk for Certified EHR Technology. §170.302(v) Encryption when exchanging electronic health information. Encrypt and decrypt electronic health information when exchanged in accordance with the standard specified in §170.210(a)(2). | ||
| §170.302(v) - Accounting of disclosures | Interim Final Rule Text: Record disclosures made for treatment, payment, and health care operations in accordance with the standard specified in §170.210(e). | Final Rule Text: §170.302(w) Certification criterion made optional, while the text of this certification criterion remains unchanged | ||
| §170.304(a) - Computerized provider order entry | Use CPOE for medication orders directly entered by any licensed healthcare professional who can enter orders into the medical record per state, local and professional guidelines | More than 30% of unique patients with at least one medication in their medication list seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) have at least one medication order entered using CPOE | Interim Final Rule Text: Enable a user to electronically record, store, retrieve, and manage, at a minimum, the following order types: (1) Medications; (2) Laboratory; (3) Radiology/imaging; and (4) Provider referrals. | Final Rule Text: §170.304(a) Computerized provider order entry. Enable a user to electronically record, store, retrieve, and modify, at a minimum, the following order types: (1) Medications; (2) Laboratory; and (3) Radiology/imaging. |
| §170.304(b) - Electronically exchange prescription information | Generate and Transmit permissible prescriptions electronically (eRx) | More than 40% of all permissible prescriptions written by the EP are transmitted electronically using certified EHR technology | Interim Final Rule Text: Enable a user to electronically transmit medication orders (prescriptions) for patients in accordance with the standards specified in §170.205(c). | Final Rule Text: §170.304(b) Electronic prescribing. Enable a user to electronically generate and transmit prescriptions and prescription-related information in accordance with: (1) The standard specified in §170.205(b)(1) or §170.205(b)(2); and (2) The standard specified in 170.207(d). |
| §170.304(c) - Record demographics | Record demographics • preferred language • gender • race • ethnicity • date of birth | More than 50% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or Emergency department (POS 21 or 23) have Demographics recorded as structured data | Interim Final Rule Text: Enable a user to electronically record, modify, and retrieve patient demographic data including preferred language, insurance type, gender, race, ethnicity, and date of birth. | Final Rule Text: §170.304(c) Record demographics. Enable a user to electronically record, modify, and retrieve patient demographic data including preferred language, gender, race, ethnicity, and date of birth. Enable race and ethnicity to be recorded in accordance with the standard specified at 170.207(f). |
| §170.304(d) - Generate patient reminder list | Send reminders to patients per patient preference for preventive/ follow up care | More than 20% of all unique patients 65 years or older or 5 years old or younger were sent an appropriate reminder during the EHR reporting period | Interim Final Rule Text: Electronically generate, upon request, a patient reminder list for preventive or follow-up care according to patient preferences based on demographic data, specific conditions, and/or medication list. | Final Rule Text: §170.304(d) Patient reminders. Enable a user to electronically generate a patient reminder list for preventive or follow-up care according to patient preferences based on, at a minimum, the data elements included in: (1) Problem list; (2) Medication list; (3) Medication allergy list; (4) Demographics; and (5) Laboratory test results. |
| §170.304(e) - Clinical decision support | Implement one clinical decision support rule relevant to specialty or high clinical priority along with the ability to track compliance that rule | Implement one clinical decision support rule | Interim Final Rule Text: (1) Implement rules. Implement automated, electronic clinical decision support rules (in addition to drug-drug and drugallergy contraindication checking) according to specialty or clinical priorities that use demographic data, specific patient diagnoses, conditions, diagnostic test results and/or patient medication list. (2) Alerts. Automatically and electronically generate and indicate in real-time, alerts and care suggestions based upon clinical decision support rules and evidence grade. (3) Alert statistics. Automatically and electronically track, record, and generate reports on the number of alerts responded to by a user. | Final Rule Text: §170.304(e) (1) Implement rules. Implement automated, electronic clinical decision support rules (in addition to drug-drug and drugallergy contraindication checking) based on the data elements included in: problem list; medication list; demographics; and laboratory test results. (2) Notifications. Automatically and electronically generate and indicate in real-time, notifications and care suggestions based upon clinical decision support rules. |
| §170.304(f) - Electronic copy of health information | Provide patients with an electronic copy of their health information (including diagnostic test results, problem list, medication lists, medication allergies), upon request | More than 50% of all patients of the EP or the inpatient or emergency departments of the eligible hospital or CAH (POS 21 or 23) who request an electronic copy of their health information are provided it within 3 business days | Interim Final Rule Text: Enable a user to create an electronic copy of a patient’s clinical information, including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, immunizations, and procedures in: (1) Human readable format; and (2) On electronic media or through some other electronic means in accordance with: (i) One of the standards specified in §170.205(a)(1); (ii) The standard specified in §170.205(a)(2)(i)(A), or, at a minimum, the version of the standard specified in §170.205(a)(2)(i)(B); (iii) One of the standards specified in §170.205(a)(2)(ii); (iv) At a minimum, the version of the standard specified in §170.205(a)(2)(iii); and (v) The standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.304(f) Electronic copy of health information. Enable a user to create an electronic copy of a patient’s clinical information, including, at a minimum, diagnostic test results, problem list, medication list, and medication allergy list in: (1) Human readable format; and (2) On electronic media or through some other electronic means in accordance with: (i) The standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2); and (ii) For the following data elements the applicable standard must be used: (A) Problems. The standard specified in §170.207(a)(1) or, at a minimum, the version of the standard specified in §170.207(a)(2); (B)Laboratory test results. At a minimum, the version of the standard specified in §170.207(c); and (C) Medications. The standard specified in §170.207(d). |
| §170.304(g) - Timely access | Provide patients with timely electronic access to their health information (including lab results, problem list, medication lists, medication allergies) within four business days of the information being available to the EP | More than 10% of all unique patients seen by the EP are provided timely (available to the patient within four business days of being updated in the certified EHR technology) electronic access to their health information subject to the EP’s discretion to withhold certain information | Interim Final Rule Text: Enable a user to provide patients with online access to their clinical information, including, at a minimum, lab test results, problem list, medication list, medication allergy list, immunizations, and procedures. | Final Rule Text: §170.304(g) Timely access. Enable a user to provide patients with online access to their clinical information, including, at a minimum, lab test results, problem list, medication list, and medication allergy list. |
| §170.304(h) - Clinical summaries | Provide clinical summaries for patients for each office visit | Clinical summaries provided to patients for more than 50% of all office visits within 3 business days | Interim Final Rule Text: (1) Provision. Enable a user to provide clinical summaries to patients for each office visit that include, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, immunizations and procedures. (2) Provided electronically. If the clinical summary is provided electronically it must be: (i) Provided in human readable format; and (ii) On electronic media or through some other electronic means in accordance with: (A) One of the standards specified in §170.205(a)(1); (B) The standard specified in §170.205(a)(2)(i)(A), or, at a minimum, the version of the standard specified in §170.205(a)(2)(i)(B); (C) One of the standards specified in §170.205(a)(2)(ii); (D) At a minimum, the version of the standard specified in §170.205(a)(2)(iii); and (E) The standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.304(h) Clinical summaries. Enable a user to provide clinical summaries to patients for each office visit that include, at a minimum, diagnostic test results, problem list, medication list, and medication allergy list. If the clinical summary is provided electronically it must be: (1) Provided in human readable format; and (2) Provided on electronic media or through some other electronic means in accordance with: (i) The standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2); and (ii) For the following data elements the applicable standard must be used: (A) Problems. The standard specified in §170.207(a)(1) or, at a minimum, the version of the standard specified in §170.207(a)(2); (B)Laboratory test results. At a minimum, the version of the standard specified in §170.207(c); and (C) Medications. The standard specified in §170.207(d). |
| §170.304(i) - Exchange clinical information and patient summary record | Capability to exchange key clinical information (for example, problem list, medication list, medication allergies, diagnostic test results), among providers of care and patient authorized entities electronically -----------------------The EP, eligible hospital or CAH who transitions their patient to another setting of care or provider of care or refers their patient to another provider of care should provide summary of care record for each transition of care or referral | Performed at least one test of certified EHR technology's capacity to electronically exchange key clinical information ---------------------- The EP, eligible hospital or CAH who transitions or refers their patient to another setting of care or provider of care provides a summary of care record for more than 50% of transitions of care and referrals | Interim Final Rule Text: (1) Electronically receive and display. Electronically receive a patient’s summary record, from other providers and organizations including, at a minimum, diagnostic tests results, problem list, medication list, medication allergy list, immunizations, and procedures in accordance with §170.205(a) and upon receipt of a patient summary record formatted in an alternate standard specified in §170.205(a)(1), display it in human readable format. (2) Electronically transmit. Enable a user to electronically transmit a patient summary record to other providers and organizations including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, immunizations, and procedures in accordance with: (i)One of the standards specified in §170.205(a)(1); (ii)The standard specified in §170.205(a)(2)(i)(A), or, at a minimum, the version of the standard specified in §170.205(a)(2)(i)(B); (iii)One of the standards specified in §170.205(a)(2)(ii); (iv)At a minimum, the version of the standard specified in §170.205(a)(2)(iii); and (v)The standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.304(i) (1) Electronically receive and display. Electronically receive and display a patient’s summary record, from other providers and organizations including, at a minimum, diagnostic tests results, problem list, medication list, and medication allergy list in accordance with the standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2). Upon receipt of a patient summary record formatted according to the alternative standard, display it in human readable format. (2) Electronically transmit. Enable a user to electronically transmit a patient summary record to other providers and organizations including, at a minimum, diagnostic test results, problem list, medication list, and medication allergy list in accordance with: (i) The standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2); and (ii) For the following data elements the applicable standard must be used: (A) Problems. The standard specified in §170.207(a)(1) or, at a minimum, the version of the standard specified in §170.207(a)(2); (B) Laboratory test results. At a minimum, the version of the standard specified in §170.207(c); and (C) Medications. The standard specified in §170.207(d). |
| Patient Education | Use certified EHR technology to identify patient-specific education resources and provide those resources to the patient if appropriate | More than 10% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) are provided patient-specific education resources | N/A | Final Rule Text: §170.302(m) Patient-specific education resources. Enable a user to electronically identify and provide patient-specific education resources according to, at a minimum, the data elements included in the patient’s: problem list; medication list; and laboratory test results; as well as provide such resources to the patient. |
| Measure Calculation | N/A | N/A | N/A | Final Rule Text: §170.302(n) Automated measure calculation. For each meaningful use objective with a percentage-based measure, electronically record the numerator and denominator and generate a report including the numerator, denominator, and resulting percentage associated with each applicable meaningful use measure. |
| HOSPITAL ONLY CRITERIA | ||||
| §170.306(a) - Computerized provider order entry | Use CPOE for medication orders directly entered by any licensed healthcare professional who can enter orders into the medical record per state, local and professional guidelines | More than 30% of unique patients with at least one medication in their medication list seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) have at least one medication order entered using CPOE | Interim Final Rule Text: Enable a user to electronically record, store, retrieve, and manage, at a minimum, the following order types: (1) Medications; (2) Laboratory; (3) Radiology/imaging; (4) Blood bank; (5) Physical therapy; (6) Occupational therapy; (7) Respiratory therapy; (8) Rehabilitation therapy; (9) Dialysis; (10) Provider consults; and (11) Discharge and transfer. | Final Rule Text: §170.306(a) Computerized provider order entry. Enable a user to electronically record, store, retrieve, and modify, at a minimum, the following order types: (1) Medications; (2) Laboratory; and (3) Radiology/imaging. |
| §170.306(b) - Record demographics | Record demographics • preferred language • gender • race • ethnicity • date of birth • date and preliminary cause of death in the event of mortality in the eligible hospital or CAH | More than 50% of all unique patients seen by the EP or admitted to the eligible hospital’s or CAH’s inpatient or emergency department (POS 21 or 23) have demographics recorded as structured data | Interim Final Rule Text: Enable a user to electronically record, modify, and retrieve patient demographic data including preferred language, insurance type, gender, race, ethnicity, date of birth, and date and cause of death in the event of mortality. | Final Rule Text: §170.306(b) Record demographics. Enable a user to electronically record, modify, and retrieve patient demographic data including preferred language, gender, race, ethnicity, date of birth, and date and preliminary cause of death in the event of mortality. Enable race and ethnicity to be recorded in accordance with the standard specified at §170.207(f). |
| §170.306(c) - Clinical decision support | Implement one clinical decision support rule related to a high priority hospital condition along with the ability to track compliance with that rule | Implement one clinical decision support rule | Interim Final Rule Text: (1) Implement rules. Implement automated, electronic clinical decision support rules (in addition to drug-drug and drugallergy contraindication checking) according to a high priority hospital condition that use demographic data, specific patient diagnoses, conditions, diagnostic test results and/or patient medication list. (2) Alerts. Automatically and electronically generate and indicate in real-time, alerts and care suggestions based upon clinical decision support rules and evidence grade. (3) Alert statistics. Automatically and electronically track, record, and generate reports on the number of alerts responded to by a user. | Final Rule Text: §170.306(c) (1) Implement rules. Implement automated, electronic clinical decision support rules (in addition to drug-drug and drugallergy contraindication checking) based on the data elements included in: problem list; medication list; demographics; and laboratory test results. (2) Notifications. Automatically and electronically generate and indicate in real-time, notifications and care suggestions based upon clinical decision support rules. |
| §170.306(d) - Electronic copy of health information | Provide patients with an electronic copy of their health information (including diagnostic test results, problem list, medication lists, medication allergies, discharge summary, procedures), upon request | More than 50% of all patients of the EP or the inpatient or emergency departments of the eligible hospital or CAH (POS 21 or 23) who request an electronic copy of their health information are provided it within 3 business days | Interim Final Rule Text: Enable a user to create an electronic copy of a patient’s clinical information, including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, immunizations, procedures, and discharge summary in: (1) Human readable format; and (2) On electronic media or through some other electronic means in accordance with: (i) One of the standards specified in §170.205(a)(1); (ii) The standard specified in §170.205(a)(2)(i)(A), or, at a minimum, the version of the standard specified in §170.205(a)(2)(i)(B); (iii) One of the standards specified in §170.205(a)(2)(ii); (iv) At a minimum, the version of the standard specified in §170.205(a)(2)(iii); and (v) The standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.306(d) (1) Enable a user to create an electronic copy of a patient’s clinical information, including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, and procedures: (i) In human readable format; and (ii) On electronic media or through some other electronic means in accordance with: (A) The standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2); and (B) For the following data elements the applicable standard must be used: (1) Problems. The standard specified in §170.207(a)(1) or, at a minimum, the version of the standard specified in §170.207(a)(2); (2) Procedures. The standard specified in §170.207(b)(1) or §170.207(b)(2); (3) Laboratory test results. At a minimum, the version of the standard specified in §170.207(c); and (4) Medications. The standard specified in §170.207(d). (2) Enable a user to create an electronic copy of a patient’s discharge summary in human readable format and on electronic media or through some other electronic means. |
| §170.306(e) - Electronic copy of discharge information | Provide patients with an electronic copy of their discharge instructions at time of discharge, upon request | More than 50% of all patients who are discharged from an eligible hospital or CAH’s inpatient department or emergency department (POS 21 or 23) and who request an electronic copy of their discharge instructions are provided it | Interim Final Rule Text: Enable a user to create an electronic copy of the discharge instructions and procedures for a patient, in human readable format, at the time of discharge on electronic media or through some other electronic means. | Final Rule Text: §170.306(e) Electronic copy of discharge instructions. Enable a user to create an electronic copy of the discharge instructions for a patient, in human readable format, at the time of discharge on electronic media or through some other electronic means. |
| §170.306(f) - Exchange clinical information and summary record. | Capability to exchange key clinical information (for example, discharge summary, procedures, problem list, medication list, medication allergies, diagnostic test results), among providers of care and patient authorized entities electronically ---------------------- The EP, eligible hospital or CAH who transitions their patient to another setting of care or provider of care or refers their patient to another provider of care should provide summary of care record for each transition of care or referral | Performed at least one test of certified EHR technology's capacity to electronically exchange key clinical information ---------------------- The EP, eligible hospital or CAH who transitions or refers their patient to another setting of care or provider of care provides a summary of care record for more than 50% of transitions of care and referrals | Interim Final Rule Text: (1) Electronically receive and display. Electronically receive a patient’s summary record from other providers and organizations including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, immunizations, procedures, and discharge summary in accordance with §170.205(a) and upon receipt of a patient summary record formatted in an alternate standard specified in §170.205(a)(1), display it in human readable format. (2) Electronically transmit. Enable a user to electronically transmit a patient’s summary record to other providers and organizations including, at a minimum, diagnostic results, problem list, medication list, medication allergy list, immunizations, procedures, and discharge summary in accordance with: (i) One of the standards specified in §170.205(a)(1); (ii) The standard specified in §170.205(a)(2)(i)(A), or, at a minimum, the version of the standard specified in §170.205(a)(2)(i)(B); (iii) One of the standards specified in §170.205(a)(2)(ii); (iv) At a minimum, the version of the standard specified in §170.205(a)(2)(iii); and (v) The standard specified in §170.205(a)(2)(iv). | Final Rule Text: §170.306(f) (1) Electronically receive and display. Electronically receive and display a patient’s summary record from other providers and organizations including, at a minimum, diagnostic test results, problem list, medication list, medication allergy list, and procedures in accordance with the standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2). Upon receipt of a patient summary record formatted according to the alternative standard, display it in human readable format. (2) Electronically transmit. Enable a user to electronically transmit a patient’s summary record to other providers and organizations including, at a minimum, diagnostic results, problem list, medication list, medication allergy list, and procedures in accordance with: (i) The standard (and applicable implementation specifications) specified in §170.205(a)(1) or §170.205(a)(2); and (ii) For the following data elements the applicable standard must be used: (A) Problems. The standard specified in §170.207(a)(1) or, at a minimum, the version of the standard specified in §170.207(a)(2); (B) Procedures. The standard specified in §170.207(b)(1) or §170.207(b)(2); (C) Laboratory test results. At a minimum, the version of the standard specified in §170.207(c); and (D) Medications. The standard specified in §170.207(d). |
| §170.306(g) - Reportable lab results | Capability to submit electronic data on reportable (as required by state or local law) lab results to public health agencies and actual submission in accordance with applicable law and practice | Performed at least one test of certified EHR technology’s capacity to provide electronic submission of reportable lab results to public health agencies and follow-up submission if the test is successful (unless none of the public health agencies to which eligible hospital or CAH submits such information have the capacity to receive the information electronically) | Interim Final Rule Text: Electronically record, retrieve, and transmit reportable clinical lab results to public health agencies in accordance with the standard specified in §170.205(f)(1) and, at a minimum, the version of the standard specified in §170.205(f)(2). | Final Rule Text: §170.306(g) Reportable lab results. Electronically record, modify, retrieve, and submit reportable clinical lab results in accordance with the standard (and applicable implementation specifications) specified in §170.205(c) and, at a minimum, the version of the standard specified in §170.207(c). |
| Record Advance Directives | Record advance directives for patients 65 years old or older | More than 50% of all unique patients 65 years old or older admitted to the eligible hospital’s or CAH’s inpatient department (POS 21) have an indication of an advance directive status recorded | N/A | Final Rule Text: §170.306(h) Advance directives. Enable a user to electronically record whether a patient has an advance directive. |

Subscribe to:
Posts (Atom)
